欢迎访问ic37.com |
会员登录 免费注册
发布采购

MC1558JG 参数 Datasheet PDF下载

MC1558JG图片预览
型号: MC1558JG
PDF下载: 下载PDF文件 查看货源
内容描述: 双路通用运算放大器 [DUAL GENERAL-PURPOSE OPERATIONAL AMPLIFIERS]
分类和应用: 运算放大器放大器电路PC
文件页数/大小: 13 页 / 296 K
品牌: TI [ TEXAS INSTRUMENTS ]
 浏览型号MC1558JG的Datasheet PDF文件第1页浏览型号MC1558JG的Datasheet PDF文件第2页浏览型号MC1558JG的Datasheet PDF文件第4页浏览型号MC1558JG的Datasheet PDF文件第5页浏览型号MC1558JG的Datasheet PDF文件第6页浏览型号MC1558JG的Datasheet PDF文件第7页浏览型号MC1558JG的Datasheet PDF文件第8页浏览型号MC1558JG的Datasheet PDF文件第9页  
MC1458, MC1558
DUAL GENERAL-PURPOSE OPERATIONAL AMPLIFIERS
SLOS069B – FEBRUARY 1971 – REVISED SEPTEMBER 2002
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC+
(see Note 1): MC1458 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 V
MC1558 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 V
Supply voltage, V
CC–
(see Note 1): MC1458 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –18 V
MC1558 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –22 V
Differential input voltage, V
ID
(see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±30
V
Input voltage, V
I
(either input, see Notes 1 and 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±15
V
Duration of output short circuit (see Note 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unlimited
Operating virtual junction temperature, T
J
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150°C
Package thermal impedance,
θ
JA
(see Notes 5 and 6): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97°C/W
P package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85°C/W
PS package . . . . . . . . . . . . . . . . . . . . . . . . . . . 95°C/W
Package thermal impedance,
θ
JC
(see Notes 7 and 8): FK package . . . . . . . . . . . . . . . . . . . . . . . . . 5.61°C/W
JG package . . . . . . . . . . . . . . . . . . . . . . . . . 14.5°C/W
Case temperature for 60 seconds: FK package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: JG package . . . . . . . . . . . . . . . . . . . . 300°C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: D, P, or PS package . . . . . . . . . . . . . 260°C
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, unless otherwise noted, are with respect to the midpoint between VCC+ and VCC– .
2. Differential voltages are at IN+ with respect to IN –.
3. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less.
4. The output can be shorted to ground or either power supply. For the MC1558 only, the unlimited duration of the short circuit applies
at (or below) 125°C case temperature or 70°C free-air temperature.
5. Maximum power dissipation is a function of TJ(max),
θ
JA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) – TA)/
θ
JA. Operating at the absolute maximum TJ of 150°C can affect reliability.
6. The package thermal impedance is calculated in accordance with JESD 51-7.
7. Maximum power dissipation is a function of TJ(max),
θ
JC, and TC. The maximum allowable power dissipation at any allowable case
temperature is PD = (TJ(max) – TC)/
θ
JC. Operating at the absolute maximum TJ of 150°C can affect reliability.
8. The package thermal impedance is calculated in accordance with MIL-STD-883.
recommended operating conditions
MIN
VCC
±
TA
Supply voltage
Operating free-air temperature range
free air
MC1458
MC1558
±
5
0
–55
MAX
±
15
70
125
UNIT
V
°C
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
3