MAX232, MAX232I
DUAL EIA-232 DRIVER/RECEIVER
SLLS047G – FEBRUARY 1989 – REVISED AUGUST 1998
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Input supply voltage range, V
CC
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to 6 V
Positive output supply voltage range, V
S+
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
CC
– 0.3 V to 15 V
Negative output supply voltage range, V
S –
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to –15 V
Input voltage range, V
I
: Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to V
CC
+ 0.3 V
Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±
30 V
Output voltage range, V
O
: T1OUT, T2OUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
S –
– 0.3 V to V
S+
+ 0.3 V
R1OUT, R2OUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to V
CC
+ 0.3 V
Short-circuit duration: T1OUT, T2OUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unlimited
Package thermal impedance,
θ
JA
(see Note 2): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113°C/W
DW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105°C/W
N package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78°C/W
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to network ground terminal.
2. The package thermal impedance is calculated in accordance with JESD 51, except for through-hole packages, which use a trace length
of zero.
recommended operating conditions
MIN
Supply voltage, VCC
High-level input voltage, VIH (T1IN,T2IN)
Low-level input voltage, VIL (T1IN, T2IN)
Receiver input voltage, R1IN, R2IN
Operating free-air temperature,TA
free air temperature T
MAX232
MAX232I
0
–40
4.5
2
0.8
±30
70
85
NOM
5
MAX
5.5
UNIT
V
V
V
V
°C
2
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265