 浏览型号LP2951CN-3.3/NOPB的Datasheet PDF文件第29页浏览型号LP2951CN-3.3/NOPB的Datasheet PDF文件第30页浏览型号LP2951CN-3.3/NOPB的Datasheet PDF文件第31页浏览型号LP2951CN-3.3/NOPB的Datasheet PDF文件第32页浏览型号LP2951CN-3.3/NOPB的Datasheet PDF文件第34页浏览型号LP2951CN-3.3/NOPB的Datasheet PDF文件第35页浏览型号LP2951CN-3.3/NOPB的Datasheet PDF文件第36页浏览型号LP2951CN-3.3/NOPB的Datasheet PDF文件第37页  
LP2950-N, LP2951-N  
www.ti.com  
SNVS764Q JANUARY 2000REVISED DECEMBER 2017  
Layout Example (continued)  
Ground  
Output  
Input  
Capacitor  
Capacitor  
Exposed  
Thermal Pad  
IN  
1
2
3
4
8
VIN  
OUT  
SENSE  
VOUT  
7
FEEDBACK  
VTAP  
SHUTDOWN  
6
5
Error Pullup  
Resistor  
6 Thermal Vias  
Ground  
ERROR  
VOUT  
GND  
Figure 58. LP2951 WSON Board Layout  
11.3 WSON Mounting  
The NGT (no pullback) 8-lead WSON package requires specific mounting techniques which are detailed in AN-  
1187 Leadless Leadframe Package (LLP). Referring to the PCB Design Recommendations section, note that the  
pad style which should be used with the WSON package is the NSMD (non-solder mask defined) type.  
Additionally, TI recommends that the PCB terminal pads to be 0.2 mm longer than the package pads to create a  
solder fillet to improve reliability and inspection.  
The thermal dissipation of the WSON package is directly related to the printed circuit board construction and the  
amount of additional copper area connected to the DAP.  
For the LP2951-N in the NGT 8-lead WSON package, the junction-to-case thermal rating, RθJC, is 35°C/W, where  
the case is the bottom of the package at the center of the DAP.  
The DAP (exposed pad) on the bottom of the WSON package is connected to the die substrate with a conductive  
die attach adhesive. The DAP has no direct electrical (wire) connection to any of the eight pins. There is a  
parasitic PN junction between the die substrate and the device ground. As such, it is strongly recommend that  
the DAP be connected directly to the ground at device lead 4 (that is, GND). Alternately, but not recommended,  
the DAP may be left floating (that is, no electrical connection). The DAP must not be connected to any potential  
other than ground.  