LMV331 SINGLE, LMV393 DUAL, LMV339 QUAD
GENERAL-PURPOSE LOW-VOLTAGE COMPARATORS
SLCS136C – AUGUST 1999 – REVISED APRIL 2000
AVAILABLE OPTIONS
PACKAGED DEVICES
PACKAGE
TYPE
T
A
SINGLE
DUAL
QUADRUPLE
LMV331IDCKR
LMV331IDBVR
—
—
—
—
5-pin SOT
8-pin SOIC
8-pin TSSOP
—
—
LMV393ID
LMV393IPWR
—
—
–40°C to 85°C
14-pin SOIC
14-pin TSSOP
—
—
LMV339ID
LMV339IPWR
—
The D package is available taped and reeled. Add the suffix R to the device type (e.g.,
LMV393DR). The DCK, DBV, and PW packages are only available left-end taped and
reeled.
†
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
CC+
Differential input voltage, V (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±5.5 V
Input voltage range, V (either input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 5.5°C
Operating virtual junction temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 150°C
ID
I
Package thermal impedance, θ (see Notes 3 and 4): D (8-pin) package . . . . . . . . . . . . . . . . . . . . . . 97°C/W
JA
D (14-pin) package . . . . . . . . . . . . . . . . . . . . 86°C/W
DBV package . . . . . . . . . . . . . . . . . . . . . . . 347°C/W
DCK package . . . . . . . . . . . . . . . . . . . . . . . 389°C/W
PW (8-pin) package . . . . . . . . . . . . . . . . . . 149°C/W
PW (14-pin) package . . . . . . . . . . . . . . . . . . 113°C/W
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D or PW package . . . . . . . . . . . . . . . 260°C
Storage temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65 to 150°C
stg
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. Allvoltagevalues(exceptdifferentialvoltagesandV
2. Differential voltages are at IN+ with respect to IN–.
specifiedforthemeasurementofI )arewithrespecttothenetworkGND.
OS
CC+
3. Maximum power dissipation is a function of T (max), θ , and T . The maximum allowable power dissipation at any allowable
JA
J
A
ambient temperature is P = (T (max) – T )/θ . Selecting the maximum of 150°C can affect reliability.
D
J
A
JA
4. The package thermal impedance is calculated in accordance with JESD 51.
recommended operating conditions
MIN
2.7
MAX
5.5
UNIT
V
V
Supply voltage (single-supply operation)
Operating free-air temperature
CC+
T
A
–40
85
°C
PRODUCT PREVIEW information concerns products in the formative or
design phase of development. Characteristic data and other
specifications are design goals. Texas Instruments reserves the right to
change or discontinue these products without notice.
2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265