SNIS160D – MAY 1999 – REVISED MARCH 2013
Absolute Maximum Ratings
(1) (2)
Reverse Current
Forward Current
Storage Temperature
8-Pin SOIC Package
TO-92 Package
TO Package
Specified Operating Temp. Range
Continuous
LM135, LM135A
LM235, LM235A
LM335, LM335A
Lead Temp. (Soldering, 10 seconds)
8-Pin SOIC Package:
Vapor Phase (60 seconds):
Infrared (15 seconds):
TO-92 Package:
TO Package:
(1)
(2)
(3)
300°C
215°C
220°C
260°C
300°C
−55°C
to 150°C
−40°C
to 125°C
−40°C
to 100°C
Intermittent
(3)
150°C to 200°C
125°C to 150°C
100°C to 125°C
−65°C
to 150°C
−60°C
to 150°C
−60°C
to 180°C
15 mA
10 mA
Refer to RETS135H for military specifications.
If Military/Aerospace specified devices are required, please contact the TI Sales Office/Distributors for availability and specifications.
Continuous operation at these temperatures for 10,000 hours for NDV package and 5,000 hours for LP package may decrease life
expectancy of the device.
Temperature Accuracy
(1)
LM135/LM235, LM135A/LM235A
Parameter
Operating Output Voltage
Uncalibrated Temperature Error
Uncalibrated Temperature Error
Temperature Error with 25°C
Calibration
Calibrated Error at Extended
Temperatures
Non-Linearity
(1)
I
R
= 1 mA
0.3
0.5
0.3
1
°C
T
C
= T
MAX
(Intermittent)
2
2
°C
Conditions
T
C
= 25°C, I
R
= 1 mA
T
C
= 25°C, I
R
= 1 mA
T
MIN
≤
T
C
≤
T
MAX
, I
R
= 1 mA
T
MIN
≤
T
C
≤
T
MAX
, I
R
= 1 mA
LM135A/LM235A
Min
2.97
Typ
2.98
0.5
1.3
0.3
Max
2.99
1
2.7
1
Min
2.95
LM135/LM235
Typ
2.98
1
2
0.5
Max
3.01
3
5
1.5
V
°C
°C
°C
Units
Accuracy measurements are made in a well-stirred oil bath. For other conditions, self heating must be considered.
Temperature Accuracy
(1)
LM335, LM335A
Parameter
Operating Output Voltage
Uncalibrated Temperature Error
Uncalibrated Temperature Error
Temperature Error with 25°C
Calibration
Calibrated Error at Extended
Temperatures
Non-Linearity
(1)
2
I
R
= 1 mA
0.3
1.5
0.3
1.5
°C
T
C
= T
MAX
(Intermittent)
2
2
°C
Conditions
Min
T
C
= 25°C, I
R
= 1 mA
T
C
= 25°C, I
R
= 1 mA
T
MIN
≤
T
C
≤
T
MAX
, I
R
= 1 mA
T
MIN
≤
T
C
≤
T
MAX
, I
R
= 1 mA
2.95
LM335A
Typ
2.98
1
2
0.5
Max
3.01
3
5
1
Min
2.92
LM335
Typ
2.98
2
4
1
Max
3.04
6
9
2
V
°C
°C
°C
Units
Accuracy measurements are made in a well-stirred oil bath. For other conditions, self heating must be considered.
Copyright © 1999–2013, Texas Instruments Incorporated