absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
LM2902
Supply voltage, VCC (see Note 1)
Differential input voltage, VID (see Note 2)
Input voltage, VI (either input)
Duration of output short circuit (one amplifier) to ground at (or below) TA = 25°C,
VCC
15 V (see Note 3)
D package
DB package
Package thermal impedance,
θ
JA (see Notes 4 and 5)
N package
NS package
PW package
FK package
Package thermal impedance,
q
JC (see Notes 6 and 7)
Operating virtual junction temperature, TJ
Case temperature for 60 seconds
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds
Storage temperature range, Tstg
FK package
J or W package
300
−65 to 150
J package
W package
150
±13
or 26
±26
−0.3 to 26
Unlimited
86
96
80
76
113
ALL OTHER
DEVICES
±16
or 32
±32
−0.3 to 32
Unlimited
86
96
80
76
113
5.61
15.05
14.65
150
260
300
−65 to 150
°C
°C
°C
°C
°C/W
C/W
°C/W
C/W
UNIT
V
V
V
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values (except differential voltages and VCC specified for the measurement of IOS) are with respect to the network GND.
2. Differential voltages are at IN+, with respect to IN−.
3. Short circuits from outputs to VCC can cause excessive heating and eventual destruction.
4. Maximum power dissipation is a function of TJ(max),
q
JA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) − TA)/qJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
5. The package thermal impedance is calculated in accordance with JESD 51-7.
6. Maximum power dissipation is a function of TJ(max),
q
JC, and TC. The maximum allowable power dissipation at any allowable case
temperature is PD = (TJ(max) − TC)/qJC. Operating at the absolute maximum TJ of 150°C can affect reliability.
7. The package thermal impedance is calculated in accordance with MIL-STD-883.
ESD protection
TEST CONDITIONS
Human-Body Model
LM224K, LM224KA, LM324K, LM324KA, LM2902K, LM2902KV, LM2902KAV
TYP
±2
UNIT
kV
POST OFFICE BOX 655303
DALLAS, TEXAS 75265