LM124, LM124A, LM224, LM224A, LM324, LM324A, LM2902, LM2902V,
LM224K, LM224KA, LM324K, LM324KA, LM2902K, LM2902KV, LM2902KAV
QUADRUPLE OPERATIONAL AMPLIFIERS
SLOS066T − SEPTEMBER 1975 − REVISED MARCH 2010
electrical characteristics at specified free-air temperature, V
CC
= 5 V (unless otherwise noted)
PARAMETER
TEST
CONDITIONS
†
T
A
‡
LM124
LM224
MIN
TYP
§
3
MAX
5
7
2
30
100
−20
−150
−300
0 to
V
CC
− 1.5
0 to
V
CC
− 2
V
CC
− 1.5
26
27
28
5
50
25
70
80
100
20
25
15
65
0 to
V
CC
− 1.5
0 to
V
CC
− 2
V
CC
− 1.5
26
27
MIN
LM324
LM324K
TYP
§
3
MAX
7
9
2
50
150
−20
−250
−500
UNIT
V
IO
I
IO
I
IB
Input offset voltage
V
CC
= 5 V to MAX,
V
O
= 1.4 V
V
IC
= V
ICR
min,
V
O
= 1 4 V
1.4
V
O
= 1 4 V
1.4
25°C
Full range
25°C
mV
Input offset current
Full range
25°C
nA
Input bias current
Full range
25°C
nA
V
ICR
Common-mode
input voltage range
V
CC
= 5 V to MAX
Full range
R
L
= 2 kΩ
25°C
25°C
R
L
= 2 kΩ
R
L
≥
10 kΩ
Full range
Full range
Full range
25°C
Full range
25°C
V
V
OH
High-level
output voltage
p
g
R
L
= 10 kΩ
V
CC
= MAX
V
28
5
100
V/mV
20
mV
V
OL
Low-level
output voltage
Large-signal
differential voltage
amplification
Common-mode
rejection ratio
Supply-voltage
rejection ratio
(∆V
CC
/∆V
IO
)
Crosstalk
attenuation
R
L
≤
10 kΩ
V
CC
= 15 V, V
O
= 1 V to 11 V,
R
L
≥
2 kΩ
V
IC
= V
ICR
min
A
VD
CMRR
80
dB
k
SVR
25°C
65
100
65
100
dB
V
O1
/ V
O2
f = 1 kHz to 20 kHz
V
CC
= 15 V,
V
ID
= 1 V
V,
V
O
= 0
25°C
25°C
−20
−10
10
5
12
120
−30
−60
−20
−10
120
−30
−60
dB
Source
Full range
25°C
Sink
Full range
V
O
= 200 mV
V
O
= 0,
No load
No load
25°C
25°C
Full range
Full range
5
30
±40
0.7
1.4
±60
1.2
3
12
30
±40
0.7
1.4
±60
1.2
3
mA
µA
mA
mA
20
10
20
I
O
Output current
p
V
CC
= 15 V,
V
ID
= −1 V,
1V
V
O
= 15 V
V
ID
= −1 V,
V
CC
at 5 V,
GND at −5 V
V
O
= 2.5 V,
V
CC
= MAX,
V
O
= 0.5 V
CC
,
I
OS
Short-circuit
output current
Supply current
(four amplifiers)
I
CC
†
All characteristics are measured under open-loop conditions, with zero common-mode input voltage, unless otherwise specified. MAX V
CC
for
testing purposes is 26 V for LM2902 and 30 V for the others.
‡
Full range is −55°C to 125°C for LM124, −25°C to 85°C for LM224, and 0°C to 70°C for LM324.
§
All typical values are at T = 25°C.
A
6
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265