SLOS066R − SEPTEMBER 1975 − REVISED JANUARY 2005  
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
ALL OTHER  
LM2902  
UNIT  
DEVICES  
16 or 32  
32  
Supply voltage, V  
CC  
(see Note 1)  
13 or 26  
26  
V
V
V
Differential input voltage, V (see Note 2)  
ID  
Input voltage, V (either input)  
−0.3 to 26  
−0.3 to 32  
I
Duration of output short circuit (one amplifier) to ground at (or below) T = 25°C,  
A
Unlimited  
Unlimited  
V
CC  
15 V (see Note 3)  
D package  
DB package  
N package  
NS package  
PW package  
FK package  
J package  
86  
96  
86  
96  
80  
80  
Package thermal impedance, θ (see Notes 4 and 5)  
JA  
°C/W  
°C/W  
76  
76  
113  
113  
5.61  
15.05  
14.65  
150  
Package thermal impedance, q  
(see Notes 6 and 7)  
JC  
W package  
Operating virtual junction temperature, T  
Case temperature for 60 seconds  
150  
°C  
°C  
°C  
°C  
J
FK package  
260  
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds  
Storage temperature range, T  
J or W package  
300  
300  
−65 to 150  
−65 to 150  
stg  
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and  
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
NOTES: 1. All voltage values (except differential voltages and V  
specified for the measurement of I ) are with respect to the network GND.  
CC  
OS  
2. Differential voltages are at IN+, with respect to IN−.  
3. Short circuits from outputs to V can cause excessive heating and eventual destruction.  
CC  
4. Maximum power dissipation is a function of T (max), q , and T . The maximum allowable power dissipation at any allowable  
JA  
J
A
ambient temperature is P = (T (max) − T )/q . Operating at the absolute maximum T of 150°C can affect reliability.  
D
J
A
JA  
5. The package thermal impedance is calculated in accordance with JESD 51-7.  
6. Maximum power dissipation is a function of T (max), q , and T . The maximum allowable power dissipation at any allowable case  
J
J
JC  
C
temperature is P = (T (max) − T )/q . Operating at the absolute maximum T of 150°C can affect reliability.  
7. The package thermal impedance is calculated in accordance with MIL-STD-883.  
D
J
C
JC  
J
ESD protection  
TEST CONDITIONS  
TYP  
UNIT  
Human-Body Model  
LM224K, LM224KA, LM324K, LM324KA, LM2902K, LM2902KV, LM2902KAV  
2
kV  
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265