LM111, LM211, LM311, LM311Y
DIFFERENTIAL COMPARATORS WITH STROBES
SLCS007A – SEPTEMBER 1973 – REVISED FEBRUARY 1992
electrical characteristics at specified free-air temperature, V
= ±15 V (unless otherwise noted)
CC
±
LM111, LM211
LM311
†
PARAMETER
TEST CONDITIONS
UNIT
T
A
‡
‡
MIN TYP
MAX
3
MIN TYP
MAX
7.5
10
25°C
Full range
25°C
0.7
4
2
V
IO
Input offset voltage
Input offset current
Input bias current
See Note 5
mV
4
10
6
50
I
IO
See Note 5
nA
Full range
25°C
20
70
75
100
150
100
250
300
I
IB
V
V
= 1 V to 14 V
nA
O
Full range
Low-level strobe
current (see Note 6)
I
= 0.3 V,
V ≤ –10 mV
ID
25°C
–3
–3
mA
IL(S)
(strobe)
13
to
13.8
to
13
to
13.8
to
Common-mode
input voltage range
V
ICR
Full range
V
–14.5 –14.7
–14.5 –14.7
Large-signal
differential voltage
amplification
A
V
= 5 V to 35 V,
R
= 1 kΩ
25°C
40
200
0.2
40
200
V/mV
VD
O
L
I
= –3 mA,
25°C
Full range
25°C
10
nA
µA
nA
(strobe)
High-level (collector)
output current
I
V
= 5 mV,
V
V
V
V
= 35 V
= 35 V
0.5
OH
ID
ID
OH
V
= 5 mV,
= 50 mA
= 4.5 V,
0.2
50
OH
= –5 mV
25°C
0.75
0.23
1.5
0.4
ID
ID
I
OL
= –10 mV
25°C
0.75
1.5
Low-level
(collector-to-emitter)
output voltage
V
OL
V
V
V
I
V
= –6 mV
Full range
CC+
CC–
OL
ID
ID
= 0,
= 8 mA
V
= –10 mV Full range
0.23
5.1
0.4
7.5
Supply current from
I
I
V
= –10 mV,
No load
No load
25°C
25°C
5.1
6
mA
mA
CC+
ID
ID
V , output low
CC+
Supply current from
, output high
V
= 10 mV,
–4.1
–5
–4.1
–5
CC–
V
CC–
†
Unless otherwise noted, all characteristics are measured with BALANCE and BAL/STRB open and the emitter output grounded.
Full range for LM111 is –55°C to 125°C, for LM211 is –40°C to 85°C, and for LM311 is 0°C to 70°C.
‡
All typical values are at T = 25°C.
A
NOTES: 5. The offset voltages and offset currents given are the maximum values required to drive the collector output up to 14 V or down to
1 V with a pullup resistor of 7.5 kΩ to V . These parameters actually define an error band and take into account the worst-case
CC+
effects of voltage gain and input impedance.
6. The strobe should not be shorted to ground; it should be current driven at –3 mA to –5 mA (see Figures 13 and 27).
switching characteristics, V
= ±15 V, T = 25°C
A
CC
±
LM111, LM211, LM311
PARAMETER
TEST CONDITIONS
UNIT
MIN
TYP
115
165
MAX
Response time, low-to-high-level output
Response time, high-to-low-level output
ns
ns
R
= 500 Ω to 5 V,
C
= 5 pF,
L
See Note 7
C
NOTE 7: The response time specified is for a 100-mV input step with 5-mV overdrive and is the interval between the input step function and the
instant when the output crosses 1.4 V.
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265