LM111, LM211, LM311
DIFFERENTIAL COMPARATORS WITH STROBES
SLCS007H − SEPTEMBER 1973 − REVISED AUGUST 2003
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage: V
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 V
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −18 V
CC+
CC−
CC+
V
V
− V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 V
CC−
Differential input voltage, V (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 V
ID
Input voltage, V (either input, see Notes 1 and 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 V
I
Voltage from emitter output to V
Voltage from collector output to V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 V
: LM111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 V
LM211 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 V
LM211Q . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 V
LM311 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 V
CC−
CC−
Duration of output short circuit (see Note 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 s
Package thermal impedance, θ (see Notes 5 and 6): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97°C/W
JA
P package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85°C/W
PS package . . . . . . . . . . . . . . . . . . . . . . . . . . . 95°C/W
PW package . . . . . . . . . . . . . . . . . . . . . . . . . 149°C/W
Package thermal impedance, θ (see Notes 7 and 8): FK package . . . . . . . . . . . . . . . . . . . . . . . . . 5.61°C/W
JC
JG package . . . . . . . . . . . . . . . . . . . . . . . . . 14.5°C/W
Operating virtual junction temperature, T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150°C
J
Case temperature for 60 seconds: FK package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: J or JG package . . . . . . . . . . . . . . . . 300°C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: D, P, PS, or PW package . . . . . . . . 260°C
Storage temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
stg
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, unless otherwise noted, are with respect to the midpoint between V
2. Differential voltages are at IN+ with respect to IN−.
and V
.
CC+
CC−
3. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less.
4. The output may be shorted to ground or either power supply.
5. Maximum power dissipation is a function of T (max), θJA, and T . The maximum allowable power dissipation at any allowable
A
ambient temperature is P = (T (max) − T )/θJJA. Operating at the absolute maximum T of 150°C can affect reliability.
D
J
A
J
6. The package thermal impedance is calculated in accordance with JESD 51-7.
7. Maximum power dissipation is a function of T (max), θJC, and T . The maximum allowable power dissipation at any allowable case
J
C
temperature is P = (T (max) − T )/θJC. Operating at the absolute maximum T of 150°C can affect reliability.
D
J
C
J
8. The package thermal impedance is calculated in accordance with MIL-STD-883.
recommended operating conditions
MIN
3.5
MAX
30
UNIT
V
V
V
− V
Supply voltage
CC+
CC−
Input voltage (|V
| ≤ 15 V)
V
CC−
+0.5
−55
−40
−40
0
V −1.5
CC+
V
I
CC
LM111
LM211
LM211Q
LM311
125
85
T
A
Operating free-air temperature range
°C
125
70
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265