LM2676  
www.ti.com  
SNVS031J APRIL 2000REVISED APRIL 2013  
Operating Ratings  
Supply Voltage  
8V to 40V  
Junction Temperature Range (TJ)  
40°C to 125°C  
Electrical Characteristics  
LM2676-3.3  
Limits appearing in bold type face apply over the entire junction temperature range of operation, 40°C to 125°C.  
Specifications appearing in normal type apply for TA = TJ = 25°C.  
Symbol  
VOUT  
η
Parameter  
Output Voltage  
Efficiency  
Conditions  
VIN = 8V to 40V, 100mA IOUT 3A  
VIN = 12V, ILOAD = 3A  
Typ(1)  
3.3  
Min(2)  
Max(2)  
Units  
V
3.234/3.201  
3.366/3.399  
86  
%
(1) Typical values are determined with TA = TJ = 25°C and represent the most likely norm.  
(2) All limits are ensured at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature  
limits are 100% tested during production with TA = TJ = 25°C. All limits at temperature extremes are ensured via correlation using  
standard Quality Control (SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).  
LM2676-5.0  
Symbol  
VOUT  
η
Parameter  
Output Voltage  
Efficiency  
Conditions  
VIN = 8V to 40V, 100mA IOUT 3A  
VIN = 12V, ILOAD = 3A  
Typ(1)  
5.0  
Min(2)  
Max(2)  
Units  
V
4.900/4.850  
5.100/5.150  
88  
%
(1) Typical values are determined with TA = TJ = 25°C and represent the most likely norm.  
(2) All limits are ensured at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature  
limits are 100% tested during production with TA = TJ = 25°C. All limits at temperature extremes are ensured via correlation using  
standard Quality Control (SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).  
LM2676-12  
Symbol  
VOUT  
η
Parameter  
Output Voltage  
Efficiency  
Conditions  
VIN = 15V to 40V, 100mA IOUT 3A  
VIN = 24V, ILOAD = 3A  
Typ(1)  
12  
Min(2)  
Max(2)  
Units  
V
11.76/11.64  
12.24/12.36  
94  
%
(1) Typical values are determined with TA = TJ = 25°C and represent the most likely norm.  
(2) All limits are ensured at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature  
limits are 100% tested during production with TA = TJ = 25°C. All limits at temperature extremes are ensured via correlation using  
standard Quality Control (SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).  
LM2676-ADJ  
Symbol  
Parameter  
Conditions  
Typ(1)  
1.21  
88  
Min(2)  
Max(2)  
Units  
V
VFB  
Feedback Voltage VIN = 8V to 40V, 100mA IOUT 3A  
1.186/1.174  
1.234/1.246  
VOUT Programmed for 5V  
η
Efficiency  
VIN = 12V, ILOAD = 3A  
%
(1) Typical values are determined with TA = TJ = 25°C and represent the most likely norm.  
(2) All limits are ensured at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature  
limits are 100% tested during production with TA = TJ = 25°C. All limits at temperature extremes are ensured via correlation using  
standard Quality Control (SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).  
Copyright © 2000–2013, Texas Instruments Incorporated  
Submit Documentation Feedback  
3
Product Folder Links: LM2676