LM2676
www.ti.com
SNVS031J –APRIL 2000–REVISED APRIL 2013
Operating Ratings
Supply Voltage
8V to 40V
Junction Temperature Range (TJ)
−40°C to 125°C
Electrical Characteristics
LM2676-3.3
Limits appearing in bold type face apply over the entire junction temperature range of operation, −40°C to 125°C.
Specifications appearing in normal type apply for TA = TJ = 25°C.
Symbol
VOUT
η
Parameter
Output Voltage
Efficiency
Conditions
VIN = 8V to 40V, 100mA ≤ IOUT ≤ 3A
VIN = 12V, ILOAD = 3A
Typ(1)
3.3
Min(2)
Max(2)
Units
V
3.234/3.201
3.366/3.399
86
%
(1) Typical values are determined with TA = TJ = 25°C and represent the most likely norm.
(2) All limits are ensured at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature
limits are 100% tested during production with TA = TJ = 25°C. All limits at temperature extremes are ensured via correlation using
standard Quality Control (SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
LM2676-5.0
Symbol
VOUT
η
Parameter
Output Voltage
Efficiency
Conditions
VIN = 8V to 40V, 100mA ≤ IOUT ≤ 3A
VIN = 12V, ILOAD = 3A
Typ(1)
5.0
Min(2)
Max(2)
Units
V
4.900/4.850
5.100/5.150
88
%
(1) Typical values are determined with TA = TJ = 25°C and represent the most likely norm.
(2) All limits are ensured at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature
limits are 100% tested during production with TA = TJ = 25°C. All limits at temperature extremes are ensured via correlation using
standard Quality Control (SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
LM2676-12
Symbol
VOUT
η
Parameter
Output Voltage
Efficiency
Conditions
VIN = 15V to 40V, 100mA ≤ IOUT ≤ 3A
VIN = 24V, ILOAD = 3A
Typ(1)
12
Min(2)
Max(2)
Units
V
11.76/11.64
12.24/12.36
94
%
(1) Typical values are determined with TA = TJ = 25°C and represent the most likely norm.
(2) All limits are ensured at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature
limits are 100% tested during production with TA = TJ = 25°C. All limits at temperature extremes are ensured via correlation using
standard Quality Control (SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
LM2676-ADJ
Symbol
Parameter
Conditions
Typ(1)
1.21
88
Min(2)
Max(2)
Units
V
VFB
Feedback Voltage VIN = 8V to 40V, 100mA ≤ IOUT ≤ 3A
1.186/1.174
1.234/1.246
VOUT Programmed for 5V
η
Efficiency
VIN = 12V, ILOAD = 3A
%
(1) Typical values are determined with TA = TJ = 25°C and represent the most likely norm.
(2) All limits are ensured at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature
limits are 100% tested during production with TA = TJ = 25°C. All limits at temperature extremes are ensured via correlation using
standard Quality Control (SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
3
Product Folder Links: LM2676