Table 4. Input Capacitors for Fixed Output Voltage Application
(Assumes worst case maximum input voltage and load current for a given inductance value)
Surface Mount
Output
Voltage (V)
Inductance
(µH)
AVX TPS Series
Sprague 594D Series Kemet T495 Series
No.
2
3
*
C Code
No.
1
C Code
C7
No.
2
C Code
C8
10
15
22
33
10
15
22
33
47
10
15
22
33
47
68
100
C5
C9
*
1
C10
C13
C13
C7
3
C10
C12
C12
C8
3.3
5
2
3
*
*
2
2
2
2
3
*
C5
C5
C10
*
1
2
1
C7
2
C8
2
C12
C13
C13
C10
C10
C12
C12
C13
C13
C13
3
C11
C12
C12
C7
2
3
*
*
1
2
2
2
3
3
*
C7
C7
C10
C10
*
2
2
2
2
C7
2
3
C10
C10
C12
C12
C12
12
2
3
2
3
*
*
2
2
*
*
1
2
Through Hole
Sanyo MV-GX Series Nichicon PL Series
Output
Voltage (V)
Inductance Sanyo OS-CON SA
Panasonic HFQ
Series
(µH)
Series
No.
1
1
*
C Code
No.
2
C Code
C4
No.
1
C Code
C5
No.
1
C Code
C6
10
15
22
33
10
15
22
33
47
10
15
22
33
47
68
100
C7
C10
1
C10
C14
C12
C4
1
C18
C24
C20
C14
C14
C18
C23
C20
C18
C18
C18
C18
C23
C21
C22
1
C6
3.3
5
*
1
1
1
C13
C12
C6
*
*
C7
C7
*
1
1
1
1
1
*
2
1
1
2
C4
1
1
C6
1
C10
C14
C12
C10
C10
C10
C10
C13
C12
C11
1
1
C13
C13
C12
C6
*
*
1
1
1
*
*
1
1
1
1
1
1
*
C9
C10
C10
*
1
1
1
1
1
1
C6
1
1
1
C6
12
1
1
1
C6
*
*
1
1
1
C13
C12
C11
*
*
1
1
1
*
*
1
1
1
* Check voltage rating of capacitors to be greater than application input voltage.
No. represents the number of identical capacitor types to be connected in parallel
C Code indicates the Capacitor Reference number in Table 2 for identifying the specific component from the manufacturer.
www.national.com
20
200996 Version 2 Revision 3 Print Date/Time: 2011/03/24 16:39:24