SNVS007F – SEPTEMBER 1998 – REVISED APRIL 2013
LM2674-5.0
Symbol
V
OUT
V
OUT
η
(1)
(2)
(3)
Parameter
(3)
Conditions
V
IN
= 8V to 40V, I
LOAD
= 20 mA to 500 mA
V
IN
= 6.5V to 40V, I
LOAD
= 20 mA to 250 mA
V
IN
= 12V, I
LOAD
= 500 mA
Typical
(1)
5.0
5.0
90
Min
(2)
4.925/4.850
4.925/4.850
Max
(2)
5.075/5.150
5.075/5.150
Units
V
V
%
SYSTEM PARAMETERSTest
Circuit
Output Voltage
Output Voltage
Efficiency
Typical numbers are at 25°C and represent the most likely norm.
All limits ensured at room temperature (standard type face) and at
temperature extremes (bold type face).
All room temperature limits
are 100% production tested. All limits at
temperature extremes
are ensured via correlation using standard Statistical Quality Control
(SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
External components such as the catch diode, inductor, input and output capacitors, and voltage programming resistors can affect
switching regulator performance. When the LM2674 is used as shown in
andFigure
test circuits, system performance will
be as specified by the system parameters section of the Electrical Characteristics.
LM2674-12
Symbol
V
OUT
η
(1)
(2)
(3)
Parameter
Output Voltage
Efficiency
Conditions
V
IN
= 15V to 40V, I
LOAD
= 20 mA to 500 mA
V
IN
= 24V, I
LOAD
= 500 mA
Typical
(1)
12
94
Min
(2)
11.82/11.64
Max
(2)
12.18/12.36
Units
V
%
SYSTEM PARAMETERSTest
Circuit
(3)
Typical numbers are at 25°C and represent the most likely norm.
All limits ensured at room temperature (standard type face) and at
temperature extremes (bold type face).
All room temperature limits
are 100% production tested. All limits at
temperature extremes
are ensured via correlation using standard Statistical Quality Control
(SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
External components such as the catch diode, inductor, input and output capacitors, and voltage programming resistors can affect
switching regulator performance. When the LM2674 is used as shown in
andFigure
test circuits, system performance will
be as specified by the system parameters section of the Electrical Characteristics.
LM2674-ADJ
Symbol
V
FB
Parameter
Feedback Voltage
Conditions
V
IN
= 8V to 40V, I
LOAD
= 20 mA to 500 mA
V
OUT
Programmed for 5V
(see Circuit of
V
IN
= 6.5V to 40V, I
LOAD
= 20 mA to 250 mA
V
OUT
Programmed for 5V
(see Circuit of
V
IN
= 12V, I
LOAD
= 500 mA
Typ
(1)
Min
(2)
Max
(2)
Units
SYSTEM PARAMETERS
Test Circuit
(3)
1.210
1.192/1.174
1.228/1.246
V
V
FB
Feedback Voltage
1.210
90
1.192/1.174
1.228/1.246
V
%
η
(1)
(2)
(3)
Efficiency
Typical numbers are at 25°C and represent the most likely norm.
All limits ensured at room temperature (standard type face) and at
temperature extremes (bold type face).
All room temperature limits
are 100% production tested. All limits at
temperature extremes
are ensured via correlation using standard Statistical Quality Control
(SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
External components such as the catch diode, inductor, input and output capacitors, and voltage programming resistors can affect
switching regulator performance. When the LM2674 is used as shown in
andFigure
test circuits, system performance will
be as specified by the system parameters section of the Electrical Characteristics.
4
Product Folder Links:
Copyright © 1998–2013, Texas Instruments Incorporated