LM2596  
www.ti.com  
SNVS124C NOVEMBER 1999REVISED APRIL 2013  
CIN —68 μF/25V Tant. Sprague 595D  
470 μF/50V Elec. Panasonic HFQ  
COUT —47 μF/20V Tant. Sprague 595D  
220 μF/25V Elec. Panasonic HFQ  
Figure 37. Inverting 5V Regulator with Delayed Startup  
Figure 38. Inverting Regulator Typical Load Current  
Because of differences in the operation of the inverting regulator, the standard design procedure is not used to  
select the inductor value. In the majority of designs, a 33 μH, 3.5A inductor is the best choice. Capacitor  
selection can also be narrowed down to just a few values. Using the values shown in Figure 37 will provide good  
results in the majority of inverting designs.  
This type of inverting regulator can require relatively large amounts of input current when starting up, even with  
light loads. Input currents as high as the LM2596 current limit (approx 4.5A) are needed for at least 2 ms or  
more, until the output reaches its nominal output voltage. The actual time depends on the output voltage and the  
size of the output capacitor. Input power sources that are current limited or sources that can not deliver these  
currents without getting loaded down, may not work correctly. Because of the relatively high startup currents  
required by the inverting topology, the delayed startup feature (C1, R1 and R2) shown in Figure 37 is  
recommended. By delaying the regulator startup, the input capacitor is allowed to charge up to a higher voltage  
before the switcher begins operating. A portion of the high input current needed for startup is now supplied by the  
input capacitor (CIN). For severe start up conditions, the input capacitor can be made much larger than normal.  
INVERTING REGULATOR SHUTDOWN METHODS  
To use the ON /OFF pin in a standard buck configuration is simple, pull it below 1.3V (@25°C, referenced to  
ground) to turn regulator ON, pull it above 1.3V to shut the regulator OFF. With the inverting configuration, some  
level shifting is required, because the ground pin of the regulator is no longer at ground, but is now setting at the  
negative output voltage level. Two different shutdown methods for inverting regulators are shown in Figure 39  
and Figure 40.  