SNVS124C – NOVEMBER 1999 – REVISED APRIL 2013
LM2596-3.3 Electrical Characteristics
Specifications with standard type face are for T
J
= 25°C, and those with
boldface type
apply over
full Operating
Temperature Range
LM2596-3.3
Symbol
Parameter
(3)
Conditions
Typ
(1)
Limit
(2)
Units
(Limits)
SYSTEM PARAMETERS
V
OUT
Test Circuit
4.75V
≤
V
IN
≤
40V, 0.2A
≤
I
LOAD
≤
3A
3.3
3.168/3.135
3.432/3.465
V
V(min)
V(max)
%
Output Voltage
η
(1)
(2)
(3)
Efficiency
V
IN
= 12V, I
LOAD
= 3A
73
Typical numbers are at 25°C and represent the most likely norm.
All limits specified at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature limits
are 100% production tested. All limits at temperature extremes are ensured via correlation using standard Statistical Quality Control
(SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
External components such as the catch diode, inductor, input and output capacitors, and voltage programming resistors can affect
switching regulator system performance. When the LM2596 is used as shown in the
test circuit, system performance will be
as shown in system parameters of Electrical Characteristics section.
LM2596-5.0 Electrical Characteristics
Specifications with standard type face are for T
J
= 25°C, and those with
boldface type
apply over
full Operating
Temperature Range
LM2596-5.0
Symbol
Parameter
(3)
Conditions
Typ
(1)
Limit
(2)
Units
(Limits)
SYSTEM PARAMETERS
V
OUT
Test Circuit
7V
≤
V
IN
≤
40V, 0.2A
≤
I
LOAD
≤
3A
5.0
4.800/4.750
5.200/5.250
V
V(min)
V(max)
%
Output Voltage
η
(1)
(2)
(3)
Efficiency
V
IN
= 12V, I
LOAD
= 3A
80
Typical numbers are at 25°C and represent the most likely norm.
All limits specified at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature limits
are 100% production tested. All limits at temperature extremes are ensured via correlation using standard Statistical Quality Control
(SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
External components such as the catch diode, inductor, input and output capacitors, and voltage programming resistors can affect
switching regulator system performance. When the LM2596 is used as shown in the
test circuit, system performance will be
as shown in system parameters of Electrical Characteristics section.
LM2596-12 Electrical Characteristics
Specifications with standard type face are for T
J
= 25°C, and those with
boldface type
apply over
full Operating
Temperature Range
LM2596-12
Symbol
Parameter
(3)
Conditions
Typ
(1)
Limit
(2)
Units
(Limits)
SYSTEM PARAMETERS
V
OUT
Test Circuit
15V
≤
V
IN
≤
40V, 0.2A
≤
I
LOAD
≤
3A
12.0
11.52/11.40
12.48/12.60
V
V(min)
V(max)
%
Output Voltage
η
(1)
(2)
(3)
Efficiency
V
IN
= 25V, I
LOAD
= 3A
90
Typical numbers are at 25°C and represent the most likely norm.
All limits specified at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature limits
are 100% production tested. All limits at temperature extremes are ensured via correlation using standard Statistical Quality Control
(SQC) methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
External components such as the catch diode, inductor, input and output capacitors, and voltage programming resistors can affect
switching regulator system performance. When the LM2596 is used as shown in the
test circuit, system performance will be
as shown in system parameters of Electrical Characteristics section.
Product Folder Links:
3
Copyright © 1999–2013, Texas Instruments Incorporated