SNVS107C – JUNE 1999 – REVISED APRIL 2013
ELECTRICAL CHARACTERISTICS LM2576-5.0, LM2576HV-5.0
Specifications with standard type face are for T
J
= 25°C, and those with
and
boldface type
apply over
full Operating Temperature Range.
Symbol
Parameter
Conditions
Typ
SYSTEM PARAMETERS
and
(2)
V
OUT
Output Voltage
V
IN
= 12V, I
LOAD
= 0.5A
Circuit of
and
0.5A
≤
I
LOAD
≤
3A,
8V
≤
V
IN
≤
40V
Circuit of
and
0.5A
≤
I
LOAD
≤
3A,
8V
≤
V
IN
≤
60V
Circuit of
and
V
IN
= 12V, I
LOAD
= 3A
5.0
4.900
5.100
5.0
4.800/4.750
5.200/5.250
5.0
4.800/4.750
5.225/5.275
77
V
V(Min)
V(Max)
V
V(Min)
V(Max)
V
V(Min)
V(Max)
%
LM2576-5.0
LM2576HV-5.0
Limit
(1)
Units
(Limits)
V
OUT
Output Voltage
LM2576
Output Voltage
LM2576HV
Efficiency
V
OUT
η
(1)
(2)
All limits specified at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature limits
are 100% production tested. All limits at temperature extremes are specified via correlation using standard Statistical Quality Control
(SQC) methods.
External components such as the catch diode, inductor, input and output capacitors can affect switching regulator system performance.
When the LM2576/LM2576HV is used as shown in
and
system performance will be as shown in
ELECTRICAL CHARACTERISTICS LM2576-12, LM2576HV-12
Specifications with standard type face are for T
J
= 25°C, and those with
boldface type
apply over full Operating Temperature
Range.
Symbol
Parameter
Conditions
Typ
SYSTEM PARAMETERS Test Circuit
and
(2)
V
OUT
Output Voltage
V
IN
= 25V, I
LOAD
= 0.5A
Circuit of
and
12
11.76
12.24
V
OUT
Output Voltage
LM2576
0.5A
≤
I
LOAD
≤
3A,
15V
≤
V
IN
≤
40V
Circuit of
and
and
0.5A
≤
I
LOAD
≤
3A,
15V
≤
V
IN
≤
60V
Circuit of
and
V
IN
= 15V, I
LOAD
= 3A
12
11.52/11.40
12.48/12.60
12
11.52/11.40
12.54/12.66
88
V
V(Min)
V(Max)
V
V(Min)
V(Max)
V
V(Min)
V(Max)
%
LM2576-12
LM2576HV-12
Limit
(1)
Units
(Limits)
V
OUT
Output Voltage
LM2576HV
η
(1)
(2)
Efficiency
All limits specified at room temperature (standard type face) and at temperature extremes (bold type face). All room temperature limits
are 100% production tested. All limits at temperature extremes are specified via correlation using standard Statistical Quality Control
(SQC) methods.
External components such as the catch diode, inductor, input and output capacitors can affect switching regulator system performance.
When the LM2576/LM2576HV is used as shown in
and
system performance will be as shown in
4
Copyright © 1999–2013, Texas Instruments Incorporated
Product Folder Links: