LF353
JFET-INPUT
DUAL OPERATIONAL AMPLIFIER
SLOS012B – MARCH 1987 – REVISED AUGUST 1994
recommended operating conditions
MIN
Supply voltage, VCC +
Supply voltage, VCC –
3.5
– 3.5
MAX
18
– 18
UNIT
V
V
electrical characteristics over operating free-air temperature range, V
CC
±
=
±15
V (unless
otherwise specified)
PARAMETER
VIO
α
VIO
IIO
IIB
Input offset voltage
Average temperature coefficient of input offset
voltage
Input
Inp t offset current‡
c rrent
Input
Inp t bias current‡
c rrent
TEST CONDITIONS
VIC = 0
0,
VIC = 0,
VIC = 0
VIC = 0
RS = 10 kΩ
RS = 10 kΩ
25°C
70°C
25°C
70°C
±
11
RL = 10 kΩ
VO =
±
10 V
V,
TJ = 25°C
RS
≤
10 kΩ
See Note 2
RL = 2 kΩ
25°C
Full range
±
12
25
15
1012
70
70
100
100
– 12
to
15
±
13.5
100
50
TA†
25°C
Full range
10
25
100
4
200
8
MIN
TYP
5
MAX
10
13
UNIT
mV
µV/°C
pA
nA
pA
nA
V
V
V/mV
Ω
dB
dB
VICR
VOM
AVD
ri
CMRR
kSVR
Common-mode input voltage range
Maximum peak output voltage swing
Large signal differential voltage
Large-signal
Input resistance
Common-mode rejection ratio
Supply-voltage rejection ratio
ICC
Supply current
3.6
6.5
mA
† Full range is 0°C to 70°C.
‡ Input bias currents of a FET-input operational amplifier are normal junction reverse currents, which are temperature sensitive. Pulse techniques
must be used that will maintain the junction temperatures as close to the ambient temperature as possible.
NOTE 2: Supply-voltage rejection ratio is measured for both supply magnitudes increasing or decreasing simultaneously.
operating characteristics, V
CC
±
=
±15
V, T
A
= 25°C
PARAMETER
VO1/VO2
SR
B1
Vn
In
Crosstalk attentuation
Slew rate
Unity-gain bandwidth
Equivalent input noise voltage
Equivalent input noise current
f = 1 kHz,
f = 1 kHz
RS = 20
Ω
TEST CONDITIONS
f = 1 kHz
8
MIN
TYP
120
13
3
18
0.01
MAX
UNIT
dB
V/µs
MHz
nV/√Hz
pA/√Hz
2
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265