ICL7135C, TLC7135C
4 1/2-DIGIT PRECISION
ANALOG-TO-DIGITAL CONVERTERS
SLAS074B – DECEMBER 1986 – REVISED MAY 1999
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Supply voltage (V
CC+
with respect to V
CC –
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 V
Analog input voltage (IN – or IN +) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
CC –
to V
CC+
Reference voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
CC –
to V
CC+
Clock input voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 V to V
CC+
Operating free-air temperature range, T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: N package . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
MIN
Supply voltage, VCC+
Supply voltage, VCC–
Reference voltage, Vref
High-level input voltage, CLK, RUN/HOLD, VIH
Low-level input voltage, CLK, RUN/HOLD, VIL
Differential input voltage, VID
Maximum operating frequency, fclock (see Note 1)
Operating free-air temperature range, TA
NOTE 1: Clock frequency range extends down to 0 Hz.
VCC – +1
1.2
0
2
70
2.8
0.8
VCC+ – 0.5
4
–3
NOM
5
–5
1
MAX
6
–8
UNIT
V
V
V
V
V
V
MHz
°C
electrical characteristics, V
CC+
= 5 V, V
CC–
= 5 V, V
ref
= 1 V, f
clock
= 120 kHz, T
A
= 25
°
C (unless
otherwise noted)
PARAMETER
VOH
VOL
VON(PP)
α
VO
IIH
IIL
II
ICC +
ICC –
Cpd
High-level
High level output voltage
Low-level output voltage
Peak-to-peak output noise voltage (see Note 2)
Zero-reading temperature coefficient of output voltage
High-level input current
Low-level input current
Input leakage current IN – and IN +
current,
Positive supply current
Negative supply current
Power dissipation capacitance
D1-D5, B1,B2,B4,B8
Other outputs
TEST CONDITIONS
IO = – 1 mA
IO = – 10
µA
IO = 1.6 mA
VID = 0,
Full scale = 2 V
VID = 0,
VI = 5 V,
VI = 0 V,
VID = 0
fclock = 0
l k
fclock = 0
l k
See Note 3
0°C
≤
TA
≤
70°C
0°C
≤
TA
≤
70°C
0°C
≤
TA
≤
70°C
TA = 25°C
0°C
≤
TA
≤
70°C
TA = 25°C
0°C
≤
TA
≤
70°C
TA = 25°C
0°C
≤
TA
≤
70°C
MIN
2.4
4.9
15
0.5
0.1
– 0.02
1
1
– 0.8
40
2
10
– 0.1
10
250
2
3
–2
–3
TYP
MAX
5
5
0.4
UNIT
V
V
µV
µV/°C
µA
mA
pA
mA
mA
pF
NOTES: 2. This is the peak-to-peak value that is not exceeded 95% of the time.