CY54FCT157T, CY74FCT157T
QUAD 2-INPUT MULTIPLEXERS
WITH 3-STATE OUTPUTS
SCCS014B – MAY 1994 – REVISED NOVEMBER 2001
logic diagram (positive logic)
I0a
2
4
I1a
3
Ya
I0b
5
7
I1b
6
Yb
I0c
11
9
I1c
10
Yc
I0d
14
12
I1d
13
Yd
E
S
15
1
Pin numbers shown are for the Q and SO packages.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Supply voltage range to ground potential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
DC input voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
DC output voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 7 V
DC output current (maximum sink current/pin) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 mA
Package thermal impedance,
θ
JA
(see Note 1): Q package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90°C/W
SO package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57°C/W
Ambient temperature range with power applied, T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 135°C
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The package thermal impedance is calculated in accordance with JESD 51-7.
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265
3