欢迎访问ic37.com |
会员登录 免费注册
发布采购

CD74ACT04M96 参数 Datasheet PDF下载

CD74ACT04M96图片预览
型号: CD74ACT04M96
PDF下载: 下载PDF文件 查看货源
内容描述: 六路反向器 [HEX INVERTERS]
分类和应用: 栅极触发器逻辑集成电路光电二极管
文件页数/大小: 13 页 / 853 K
品牌: TI [ TEXAS INSTRUMENTS ]
 浏览型号CD74ACT04M96的Datasheet PDF文件第1页浏览型号CD74ACT04M96的Datasheet PDF文件第3页浏览型号CD74ACT04M96的Datasheet PDF文件第4页浏览型号CD74ACT04M96的Datasheet PDF文件第5页浏览型号CD74ACT04M96的Datasheet PDF文件第6页浏览型号CD74ACT04M96的Datasheet PDF文件第7页浏览型号CD74ACT04M96的Datasheet PDF文件第8页浏览型号CD74ACT04M96的Datasheet PDF文件第9页  
CD54ACT04, CD74ACT04  
HEX INVERTERS  
SCHS310B JANUARY 2001 REVISED JUNE 2002  
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)  
Supply voltage range, V  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 V to 6 V  
CC  
I
Input clamp current, I (V < 0 or V > V ) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA  
IK  
I
CC  
Output clamp current, I  
(V < 0 or V > V ) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA  
OK  
O O CC  
Continuous output current, I (V = 0 to V ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA  
Continuous current through V  
Package thermal impedance, θ (see Note 2): E package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80°C/W  
O
O
CC  
CC  
or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA  
JA  
M package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86°C/W  
Storage temperature range, T  
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C  
stg  
Stresses beyond those listed under absolute maximum ratingsmay cause permanent damage to the device. These are stress ratings only, and  
functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditionsis not  
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.  
2. The package thermal impedance is calculated in accordance with JESD 51-7.  
recommended operating conditions (see Note 3)  
40°C TO  
85°C  
55°C TO  
125°C  
T
A
= 25°C  
UNIT  
MIN  
4.5  
2
MAX  
MIN  
4.5  
2
MAX  
MIN  
MAX  
V
V
V
V
V
Supply voltage  
5.5  
5.5  
4.5  
2
5.5  
V
V
CC  
IH  
IL  
High-level input voltage  
Low-level input voltage  
Input voltage  
0.8  
0.8  
0.8  
V
0
0
V
V
0
0
V
V
0
0
V
V
V
I
CC  
CC  
CC  
Output voltage  
V
O
CC  
CC  
CC  
I
I
High-level output current  
Low-level output current  
24  
24  
24  
24  
24  
24  
mA  
mA  
ns/V  
OH  
OL  
t/v Input transition rise or fall rate  
10  
10  
10  
NOTE 3: All unused inputs of the device must be held at V  
or GND to ensure proper device operation. Refer to the TI application report,  
CC  
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.  
electrical characteristics over recommended operating free-air temperature range (unless  
otherwise noted)  
40°C TO  
85°C  
55°C TO  
125°C  
T
A
= 25°C  
PARAMETER  
TEST CONDITIONS  
V
CC  
UNIT  
MIN  
4.4  
MAX  
MIN  
4.4  
MAX  
MIN  
4.4  
MAX  
I
I
I
I
I
I
I
I
= 50 µA  
= 24 mA  
= 50 mA  
= 75 mA  
= 50 µA  
4.5 V  
4.5 V  
OH  
OH  
OH  
OH  
OL  
OL  
OL  
OL  
3.94  
3.8  
3.7  
V
V
V = V or V  
IH  
V
OH  
I
IL  
IL  
5.5 V  
3.85  
5.5 V  
3.85  
4.5 V  
0.1  
0.1  
0.1  
0.5  
= 24 mA  
4.5 V  
0.36  
0.44  
V = V or V  
V
OL  
I
IH  
= 50 mA  
= 75 mA  
5.5 V  
1.65  
5.5 V  
1.65  
±1  
I
I
V = V  
or GND  
or GND,  
2.1 V  
5.5 V  
±0.1  
4
±1  
80  
3
µA  
µA  
mA  
pF  
I
I
CC  
CC  
CC  
V = V  
I
I
O
= 0  
5.5 V  
40  
CC  
I  
CC  
V = V  
I
4.5 V to 5.5 V  
2.4  
10  
2.8  
10  
C
10  
i
Testoneoutputatatime, notexceeding1-secondduration. Measurementismadebyforcingindicatedcurrentandmeasuringvoltagetominimize  
power dissipation. Test verifies a minimum 50-transmission-line drive capability at 85°C and 75-transmission-line drive capability at 125°C.  
2