CD4051B, CD4052B, CD4053B
Test Circuits and Waveforms
(Continued)
V
DD
1
2
3
4
5
6
7
8
Ι
16
15
14
13
12
11
10
9
Ι
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
V
DD
V
DD
KEITHLEY
160 DIGITAL
MULTIMETER
TG
“ON”
1kΩ
RANGE
10kΩ
Y
X-Y
PLOTTER
V
SS
CD4051
CD4053
CD4052
H.P.
MOSELEY
7030A
X
FIGURE 17. QUIESCENT DEVICE CURRENT
FIGURE 18. CHANNEL ON RESISTANCE MEASUREMENT
CIRCUIT
V
DD
1
2
3
4
5
6
7
8
V
SS
16
15
14
13
12
11
10
9
CD4051
CD4053
1
2
3
4
5
6
7
8
V
SS
16
15
14
13
12
11
10
9
CD4052
V
DD
V
DD
Ι
V
SS
V
DD
Ι
V
SS
NOTE: Measure inputs sequentially,
to both V
DD
and V
SS
connect all
unused inputs to either V
DD
or V
SS
.
NOTE: Measure inputs sequentially,
to both V
DD
and V
SS
connect all
unused inputs to either V
DD
or V
SS
.
FIGURE 19. INPUT CURRENT
CHANNEL
ON
5V
P-P
V
DD
6
7
8
OFF
CHANNEL
RF
VM
1K
CHANNEL
OFF
R
L
RF
VM
COMMON
R
L
5V
P-P
CHANNEL
OFF
RF
VM
R
L
CHANNEL
ON
R
L
FIGURE 20. FEEDTHROUGH (ALL TYPES)
FIGURE 21. CROSSTALK BETWEEN ANY TWO CHANNELS
(ALL TYPES)
5V
P-P
CHANNEL IN X
ON OR OFF
R
L
CHANNEL IN Y
ON OR OFF
R
L
RF
VM
FIGURE 22. CROSSTALK BETWEEN DUALS OR TRIPLETS (CD4052B, CD4053B)
11