bq29330
www.ti.com
SLUS673A–SEPTEMBER 2005–REVISED DECEMBER 2005
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)(1)(2)
bq29330
–0.3 to 34
–0.3 to 34
–0.3 to 1.0
–1.0 to 1.0
–0.3 to 8.5
UNIT
Supply voltage range
Input voltage range
(VCC, BAT)
(VC1, VC2, VC3, VC4, PACK, PMS)
(VC5)
(SRP, SRN)
(VC1 to VC2, VC2 to VC3, VC3 to VC4, VC4
to VC5)
(WDI, SCLK, SDATA)
(DSG,CHG)
(ZVCHG)
– 0.3 to 8.5
–0.3 to BAT
–0.3 to 34
–0.3 to 34
–0.3 to 7
V
(GPOD)
Output voltage range
(TOUT, SDATA, CELL, XALERT, XRST,
LEDOUT)
(CELL+)
–0.3 to 7
10
Current for cell balancing
mA
Storage temperature range, Tstg
Lead temperature (soldering, 10 s)
–65 to 150
300
°C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to ground of this device except VCn-VC(n+1), where n=1, 2, 3, 4 cell voltage.
RECOMMENDED OPERATING CONDITIONS
MIN
4.5
5.5
0
NOM
MAX
UNIT
V
Supply voltage ( VCC,BAT)
25
VI(STARTUP) Start up voltage (VCC,BAT)
V
VC1, VC2, VC3, VC4
VC5
VDD
0.5
0
VI
Input voltage range
SRP, SRN
–0.5
0
0.5
V
VCn – VC(n+1), (n=1, 2, 3, 4 )
PACK, PMS
5.0
25
VIH
VIL
VO
0.8×REG
REG
0.2×REG
25
Logic level input voltage
Output voltage
SCLK, SDATA, WDI
V
V
V
0
GPOD
XALERT, SDATA, XRST
REG
VO
Output voltage range
CELL+, CELL–
CREG
0.975
0.1
External 2.5V REG capacitor
External LEDOUT capacitor
Extend CELL output capacitor
IOL
1.0
2.2
µF
µF
µF
mA
kΩ
kHz
µs
CLED
CCELL
GPOD
1
RPACK
1
Input frequency
WDI
32.768
WDI high time
2
–25
–40
Operating temperature
Functional temperature
85
°C
TA
110
°C
6