SLUS530H – SEPTEMBER 2002 – REVISED JUNE 2007
www.ti.com
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
ORDERING INFORMATION
T
A
CHARGE REGULATION
VOLTAGE (V)
(1)
4.2
4.2
4.2
–40°C to 125°C
4.2
4.36
(1)
(2)
(3)
OPTIONAL
FUNCTIONS
(1)
PG and TS
PG and CE
CE and TTE
CE and TS
CE and TTE
PART NUMBER
(2) (3)
bq24010DRCR
bq24012DRCR
bq24013DRCR
bq24014DRCR
bq24014DRCT
bq24018DRCR
bq24018DRCT
MARKINGS
AZN
AZR
AZO
AZR
BZH
Contact Texas Instruments for other options.
The DRC package is available only taped and reeled. Quantities are 3,000 devices per reel (e.g. bq24010DRCR) and 250 devices per
mini-reel (e.g. bq24014DRCT).
For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
website at
ABSOLUTE MAXIMUM RATINGS
(1)
VALUE
Supply voltage range, (V
CC
all with respect to V
SS
)
Input voltage range
(2)
IN, STAT1, STAT2, TS, PG, CE, TTE
BAT, OUT, ISET
STAT1, STAT2, PG
IN, OUT
–0.3 to 18
–0.3 to VCC
–0.3 to 7
±0.5
15
1.5
–40 to 125
–65 to 150
°C
°C
UNIT
V
V
VDC
V
Voltage difference between V
CC
and IN inputs V
CC
– V
IN
Output sink/source current
Output current
T
A
T
J
T
stg
(1)
(2)
Junction temperature range
Storage temperature
Operating free-air temperature range
Stresses beyond those listed under
absolute maximum ratings
may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under
recommended operating
conditions
is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
All voltages are DC and with respect to VSS.
DISSIPATION RATINGS
PACKAGE
DRC
(1)
(1)
θ
JA
47°C/W
T
A
< 40°C
POWER RATING
1.5 W
DERATING FACTOR
ABOVE T
A
= 40°C
0.021 W/°C1
This data is based on using the JEDEC High-K board and the exposed die pad is connected to a copper pad on the board. This is
connected to the ground plane by a 2x3 via matrix.
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
MIN
V
CC
V
IN
T
J
(1)
Supply voltage
(1)
Input voltage
(1)
NOM
MAX
16.5
16.5
125
UNIT
V
V
°C
3
3
–40
Operating junction temperature range
Pins V
CC
and IN must be tied together.
2