欢迎访问ic37.com |
会员登录 免费注册
发布采购

BQ20Z80DBTR 参数 Datasheet PDF下载

BQ20Z80DBTR图片预览
型号: BQ20Z80DBTR
PDF下载: 下载PDF文件 查看货源
内容描述: SBS 1.1标准的电量监测计启用Impedance Track技术为使用的bq29312A [SBS 1.1-COMPLIANT GAS GAUGE ENABLED WITH IMPEDANCE TRACK TECHNOLOGY FOR USE WITH THE bq29312A]
分类和应用: 光电二极管
文件页数/大小: 73 页 / 1137 K
品牌: TI [ TEXAS INSTRUMENTS ]
 浏览型号BQ20Z80DBTR的Datasheet PDF文件第16页浏览型号BQ20Z80DBTR的Datasheet PDF文件第17页浏览型号BQ20Z80DBTR的Datasheet PDF文件第18页浏览型号BQ20Z80DBTR的Datasheet PDF文件第19页浏览型号BQ20Z80DBTR的Datasheet PDF文件第21页浏览型号BQ20Z80DBTR的Datasheet PDF文件第22页浏览型号BQ20Z80DBTR的Datasheet PDF文件第23页浏览型号BQ20Z80DBTR的Datasheet PDF文件第24页  
bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
2nd LEVEL PROTECTION FEATURES  
The bq20z80 provides features that can be used to indicate a more serious fault via the SAFE and SAFE  
outputs. These outputs can be used to blow an in-line fuse to permanently disable the battery pack from charge  
or discharge activity.  
Actions on Detection of 2nd Level (Permanent) Failure  
When the bq20z80 SBS.PFStatus( ) changes from 0x00 to indicate a permanent failure then the following actions  
are taken in sequence.  
CHG, DSG, and ZVCHG FETs are turned OFF.  
SBS.BatteryStatus( ) [TCA, TDA] are set.  
A backup of SBS data is stored to data flash including SBS.Voltage( ), SBS.CellVoltage1( ),  
SBS.CellVoltage2( ), SBS.CellVoltage3( ), SBS.CellVoltage4( ), SBS.Current( ), SBS.Temperature( ),  
SBS.BatteryStatus( ), SBS.RemaingCapacity( ) , SBS.SafetyStatus( ), SBS.ChargingStatus( ), AFE.Data  
(complete memory map).  
Data Flash write access is then disabled, but the data flash can be read.  
SBS.ChargingCurrent( ) and SBS.ChargingVoltage( ) are set to 0.  
The appropriate bit in DF:PF Flag 1 is set.  
If the appropriate bit in DF:Permanent Fail Cfg is set, then 0x3672 is programmed to DF:Fuse Flag, the  
SAFE pin is driven and latched low, and the SAFE pin is driven and latched high.  
SBS.SafetyStatus( ) [PF] is set.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
PF Flags 1  
Fuse Flag  
0x0000 to 0xffff  
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
N/A  
N/A  
mV  
0x0000  
0x0000  
0
Hex  
0x0000 or 0x3672  
PF Voltage  
PF C1 Voltage  
PF C2 Voltage  
PF C3 Voltage  
PF C4 Voltage  
PF Current  
mV  
0
0 to 65535  
mV  
0
Integer  
mV  
0
mV  
0
2nd Level Safety / Device  
Status Data (96)  
–32768 to 32767  
–9999 to 9999  
0x0000 to 0xffff  
mA  
0
PF Temperature  
PF Batt Stat  
PF RC-mAh  
PF RC-10mWh  
PF Chg Status  
PF Safety Status  
PF Flags 2  
0.1°C  
N/A  
mAh  
10mWh  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
0
Hex  
0x0000  
0
Integer  
0 to 65535  
0
0x0000 to 0xffff  
0x0000  
0x0000  
0x0000  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
Hex  
AFE Status  
0x00 to 0xff  
0x00 to 0xff  
0x00 to 0xff  
0x00 to 0xff  
0x00 to 0xff  
0x00 to 0xff  
0x00 to 0xff  
0x00 to 0xff  
0x00 to 0xff  
AFE Output  
AFE State  
AFE Function  
AFE Cell Select  
AFE OLV  
2nd Level Safety / AFE Regs  
(97)  
Hex  
AFE OLT  
AFE SCC  
AFE SCD  
20  