bq20z80-V101  
www.ti.com  
SLUS625DSEPTEMBER 2004REVISED OCTOBER 2005  
DF:Min Cell Deviation = (500 + (2 x Rχ) ) / 0.4*3.6V, giving a default of 1750.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Min Cell Deviation Charge Control / Cell Balancing (37)  
Integer  
0 to 65535  
2
s/mAh  
1750  
Primary Charge Termination  
The bq20z80 determines charge termination when the average SBS.Current( ) during 2 consecutive periods of  
DF:Current Taper Window is < DF:Taper Current AND during the 2 consecutive periods of DF:Current Taper  
Window the accumulated change in capacity must be > 0.25mAh. If DF:TCA_Set = -1 the SBS.BatteryStaus(  
)[TCA] will be set when charge termination is detected. If DF:FC_Set = -1 the SBS.BatteryStaus( )[FC] will be set  
when charge termination is detected. If DF:Operation Cfg B [CHGFET] is set, the CHG FET is also turned off.  
For a valid charge termination to occur SBS.Voltage( )+ DF:Termination Voltage must also be DF:Fast Charge  
Voltage.  
When charge termination is detected and if DF:TCA_Set = -1, SBS.ChargingStatus( ) [MCHG] is set, and  
SBS.ChargingCurrent( ) is set to DF:Maintenance Charge Current.  
If DF:Operation Cfg B [CSYNC] is set then SBS.RemainingCapacity( ) is updated with the value in  
SBS.FullChargeCapacity( ) regardless of the setting of DF:TCA_Set.  
SBS.BatteryStatus( ) [FC] is cleared and SBS.ChargingCurrent( ) is set to the appropriate value for battery  
conditions when SBS.RelativeStateOfCharge( ) is < DF:FC Clear %.  
SBS.BatteryStatus( ) [TCA] is also cleared, and SBS.ChargingCurrent( ) is set to the appropriate value for battery  
conditions when DF:Operation Cfg B [CHGTERM] is set, AND SBS.Current( ) is < DF:Chg Current Threshold for  
two consecutive periods of DF:Current Taper Window.  
SIZE  
(BYTES)  
DEFAULT  
VALUE  
NAME  
CLASS / SUBCLASS  
FORMAT  
VALID RANGE  
UNITS  
Maintenance Charge Current  
Taper Current  
0 to 1000  
0 to 1000  
0 to 1000  
0 to 60  
2
2
2
1
0
mA  
250  
300  
40  
Charge Control /  
Termination Config. (36)  
Integer  
Termination Voltage  
Current Taper Window  
mV  
s
Charge Control SMBus Broadcasts  
All broadcasts are enabled by setting DF:Operation Cfg B [BCAST]. If DF:Operation Cfg B [HPE] is set, the  
Master-Mode broadcasts to the Host address have PEC enabled, and if DF:Operation Cfg B [CPE] is set, the  
Master-Mode broadcasts to the Smart-Charger address have PEC enabled.  
If enabled, SBS.ChargingVoltage( ) and SBS.ChargingCurrent( ) is broadcast to the Smart-Charger address  
between every 10 and 60 seconds.  
If enabled, SBS.AlarmWarning( ) is broadcast to the Host address every 10 seconds, only while any of the  
SBS.BatteryStatus( ), bits 8 -15, are set. Broadcasting stops when SBS.BatteryStatus( ), 8-15, are clear.  
If enabled, SBS.AlarmWarning( ) is broadcast to the Smart Charger address every 10 seconds only when any of  
SBS.BatteryStatus( ), bits 11 -15. Broadcasting stops when SBS.BatteryStatus( ), 11-15, are clear.  
Charging Faults  
Charge Fault Cfg  
CHARGE FAULT Fault  
CONFIGURATION  
bit7  
bit6  
bit5  
bit4  
bit3  
bit2  
bi1  
bit0  
Low Byte  
PCMTO  
FCMTO  
OCHGV  
OCHGI  
OC  
XCHGLV  
61  