Gas Discharge Tube: GC6 Series
3-Electrode
Φ6.0*T8.0
mm Type
Characteristics
DC
Spark-over
Voltage
Part No.
100V/S
(V)
GC63R090
□□(
F)
GC63R145
□□(
F)
GC63R200
□□(
F)
GC63R230
□□(
F)
GC63R250
□□(
F)
GC63R350
□□(
F)
GC63R400
□□(
F)
GC63R420
□□(
F)
GC63R470
□□(
F)
GC63R600
□□(
F)
90±20%
145±20%
200±20%
230±20%
250±20%
350±20%
400±20%
420±20%
470±20%
600±20%
100V/μs
(V)
750
750
600
600
600
650
700
700
800
900
1KV/μs
(V)
850
850
700
700
700
750
800
800
900
1000
Max. Impulse
Breakdown
Voltage
Max.
Impulse
Discharge
Current
(8/20μs)
10 times
(KA)
5
5
10
10
10
5
5
5
5
5
100
Impulse
Life
(10/1000μs)
200 A
Times
Normal
Alternating
Discharge
Current
50Hz,1Sec
(A)
5
5
10
10
10
5
5
5
5
5
DC
Holdover
Voltage
<150ms
(V)
52
52
135
135
135
150
150
150
150
150
1
2
(GΩ)
(pF)
UL 497B
√
√
√
√
√
√
√
√
√
√
Minimum
Insulation
Resistance
Maximum
Capacitance
(1MHz)
Safety
Approval
Note 1: The first
□
is the style of lead wire, and the second
□
is packaging
Note 2: F = with fail-safe clip for optional.
Note 3: UL 497B File No: E245070
Note 4: Insulation resistance test conditions:
DC Spark-over Voltage
90V
145-400V
420-600V
DC Measuring Voltage
50V
100V
250V
THINKING ELECTRONIC INDUSTRIAL Co., LTD.
All specification are subject to change without notice.
35
www.thinking.com.tw