 浏览型号73S1210F-68IM/F/P的Datasheet PDF文件第94页浏览型号73S1210F-68IM/F/P的Datasheet PDF文件第95页浏览型号73S1210F-68IM/F/P的Datasheet PDF文件第96页浏览型号73S1210F-68IM/F/P的Datasheet PDF文件第97页浏览型号73S1210F-68IM/F/P的Datasheet PDF文件第99页浏览型号73S1210F-68IM/F/P的Datasheet PDF文件第100页浏览型号73S1210F-68IM/F/P的Datasheet PDF文件第101页浏览型号73S1210F-68IM/F/P的Datasheet PDF文件第102页  
73S1210F Data Sheet  
DS_1210F_001  
CRC MS Value Registers (CRCMsB): 0xFE14 0xFF, (CRCLsB): 0xFE15 0xFF  
Table 94: The CRCMsB Register  
MSB  
LSB  
CRC.15 CRC.14 CRC.13 CRC.12 CRC.11 CRC.10  
CRC.9  
CRC.1  
CRC.8  
MSB  
CRC.7  
LSB  
CRC.6  
CRC.5  
CRC.4  
CRC.3  
CRC.2  
CRC.0  
The 16-bit CRC value forms the TX CRC word in TX mode (write value) and the RX CRC in RX mode  
(read value). The initial value of CRC to be used when generating a CRC to be transmitted at the end of  
a message (after the last TX byte is sent) when enabled in T=1 mode. Should be reloaded at the  
beginning of every message to be transmitted. When using CRC, both CRC registers should be  
initialized to FF. When using LRC, the CRCLsB value register should be loaded to 00. When receiving a  
message, the firmware should load this with the initial value and then read this register to get the final  
value at the end of the message. These registers need to be reloaded for each new message to be  
received. When in LRC mode, bits (7:0) are used and bits (15:8) are undefined. During LRC/CRC  
checking and generation, this register is updated with the current value and can be read to aid in  
debugging. This information will be transmitted to the smart card using the timing specified by the Guard  
Time register. When checking CRC/LRC on an incoming message (CRC/LRC is checked against the  
data and CRC/LRC), the firmware reads the final value after the message has been received and  
determines if an error occurred (= 0x1D0F (CRC) no error, else error; = 0 (LRC) no error, else error).  
When a message is received, the CRC/LRC is stored in the FIFO. The polynomial used to generate and  
check CRC is x16 + x12+ x5 +1. When in indirect convention, the CRC is generated prior to the conversion  
into indirect convention. When in indirect convention, the CRC is checked after the conversion out of  
indirect convention. For a given message, the CRC generated (and readable from this register) will be  
the same whether indirect or direct convention is used to transmit the data to the smart card. The  
CRCLsB / CRCMsB registers will be updated with CRC/LRC whenever bits are being received or  
transmitted from/to the smart card (even if CRCEN is not set and in mode T1). They are available to the  
firmware to use if desired.  
98  
Rev. 1.4