 浏览型号73S1209F-68IM/F的Datasheet PDF文件第84页浏览型号73S1209F-68IM/F的Datasheet PDF文件第85页浏览型号73S1209F-68IM/F的Datasheet PDF文件第86页浏览型号73S1209F-68IM/F的Datasheet PDF文件第87页浏览型号73S1209F-68IM/F的Datasheet PDF文件第89页浏览型号73S1209F-68IM/F的Datasheet PDF文件第90页浏览型号73S1209F-68IM/F的Datasheet PDF文件第91页浏览型号73S1209F-68IM/F的Datasheet PDF文件第92页  
73S1209F Data Sheet  
DS_1209F_004  
Smart Card Control Register (SCCtl): 0xFE0A Å 0x21  
This register is used to monitor reception of data from the smart card.  
Table 83: The SCCtl Register  
MSB  
LSB  
CLKLVL CLKOFF  
RSTCRD  
IO  
IOD  
C8  
C4  
Bit  
Symbol  
Function  
1 = Asserts the RST (set RST = 0) to the smart card interface, 0 = De-assert  
the RST (set RST = 1) to the smart card interface. Can be used to extend  
RST to the smart card. Refer to the RLength register description. This bit is  
operational in all modes and can be used to extend RST during activation or  
perform a “Warm Reset” as required. In auto-sequence mode, this bit  
should be set = 0 to allow the sequencer to de-assert RST per the RLength  
parameters.  
SCCtl.7  
RSTCRD  
In sync mode (see the SPrtcol register) the sense of this bit is non-inverted,  
if set =1 , RST = 1, if set = 0, RST = 0. Rlen has no effect on Reset in sync  
mode.  
SCCtl.6  
SCCtl.5  
Smart Card I/O. Read is state of I/O signal (Caution, this signal is not  
synchronized to the MPU clock). In Bypass mode, write value is state of  
signal on I/O. In sync mode, this bit will contain the value of I/O pin on the  
latest rising edge of CLK.  
IO  
Smart Card I/O Direction control Bypass mode or sync mode. 1 = input  
(default), 0 = output.  
SCCtl.4  
SCCtl.3  
IOD  
C8  
Smart Card C8. When C8 is an output, the value written to this bit will  
appear on the C8 line. The value read when C8 is an output is the value  
stored in the register. When C8 is an input, the value read is the value on  
the C8 pin (Caution, this signal is not synchronized to the MPU clock).  
When C8 is an input, the value written will be stored in the register but not  
presented to the C8 pin.  
Smart Card C4. When C4 is an output, the value written to this bit will  
appear on the C4 line. The value read when C4 is an output is the value  
stored in the register. When C4 is an input, the value read is the value on  
the C4 pin (Caution, this signal is not synchronized to the MPU clock).  
When C4 is an input, the value written will be stored in the register but not  
presented to the C4 pin.  
SCCtl.2  
C4  
1 = High, 0 = Low. If CLKOFF is set = 1, the CLK to smart card will be at the  
logic level indicated by this bit. If in bypass mode, this bit directly controls  
the state of CLK.  
SCCtl.1  
SCCtl.0  
CLKLVL  
CLKOFF  
0 = CLK is enabled. 1 = CLK is not enabled. When asserted, the CLK will  
stop at the level selected by CLKLVL. This bit has no effect if in bypass  
mode.  
88  