73M1866B/73M1966B Data Sheet
Table 15: Call Progress Monitor Specification
DS_1x66B_001
Parameter
Test Condition
Min
Nom
Max
Units
–
–
–
–
AOUT for transmit
1 kHz full swing code (ATX)
CMRXG=11 (Mute)
Observe AOUT pin
CMTXG=00
–
–
0.98
-6
–
–
Vpk
dB
CMTXG=01 relative
to CMTXG=00
CMTXG=10 relative
to CMTXG=00
–
-12
–
dB
CMTXG=11 (Mute)
CMTXG=00
–
–
–
Mute
40
–
–
–
–
dB
dB
–
AOUT transmit THD
AOUT for receive
1.0 Vpk, 1 kHz at the line or 0.5
Vpk at RXP/RXM with
RXG=10
CMTXG=11 (Mute)
Observe AOUT pin
–
–
–
–
CMRXG=00
0.96
-6
Vpk
dB
CMRXG=01 relative
to CMRXG=00
–
–
CMRXG=10 relative
to CMRXG=00
-12
dB
–
–
–
–
–
–
CMRXG=11 (Mute)
CMRXG=00
Mute
40
dB
dB
kΩ
AOUT receive THD
AOUT output
impedance
10
3.5 73M1x66B Line-Side Electrical Specifications (73M1916)
Table 16 lists the absolute maximum ratings for the line side. Operation outside these rating limits may
cause permanent damage to this device.
Table 16: Line-Side Absolute Maximum Ratings
Parameter
Min
-0.5
-0.5
Max
6.0
Unit
V
Pin input voltage from VPX to VNX
Pin input voltage (all other pins) to VNS
4.0
V
22
Rev. 1.6