 浏览型号71M6533H-IGTR/F的Datasheet PDF文件第51页浏览型号71M6533H-IGTR/F的Datasheet PDF文件第52页浏览型号71M6533H-IGTR/F的Datasheet PDF文件第53页浏览型号71M6533H-IGTR/F的Datasheet PDF文件第54页浏览型号71M6533H-IGTR/F的Datasheet PDF文件第56页浏览型号71M6533H-IGTR/F的Datasheet PDF文件第57页浏览型号71M6533H-IGTR/F的Datasheet PDF文件第58页浏览型号71M6533H-IGTR/F的Datasheet PDF文件第59页  
FDS_6533_6534_004  
71M6533/71M6534 Data Sheet  
2.3 Battery Modes  
Shortly after system power (V3P3SYS) is applied, the part will be in MISSION mode. MISSION mode  
means that the part is operating with system power and that the internal PLL is stable. This mode is the  
normal operation mode where the part is capable of measuring energy.  
When system power is not available (i.e. when V1<VBIAS), the 71M6533 and 71M6534 will be in one of  
three battery modes: BROWNOUT, LCD, or SLEEP mode. Figure 20 shows a state diagram of the vari-  
ous operation modes, with the possible transitions between modes. For information on the timing of  
mode transitions refer to Figure 24 through Figure 26.  
When V1 falls below VBIAS or the part wakes up under battery power, the part will automatically enter  
BROWNOUT mode (see Section 2.5 Wake Up Behavior). From BROWNOUT mode, the part may enter  
either LCD mode or SLEEP mode, as controlled by the MPU via the I/O RAM bits LCD_ONLY and SLEEP.  
RESET  
MISSION  
V3P3SYS  
falls  
V1 > VBIAS  
V1 <= VBIAS  
IE_PLLRISE  
IE_PLLFALL  
V3P3SYS  
rises  
V3P3SYS  
rises  
LCD_ONLY  
BROWNOUT  
V3P3SYS  
rises  
RESET &  
VBAT_OK  
IE_PB  
IE_WAKE  
PB  
SLEEP or  
VBAT_OK  
timer  
LCD  
timer  
PB  
VBAT_OK  
VBAT_OK  
RESET &  
VBAT_OK  
SLEEP  
Figure 20: Operation Modes State Diagram  
The transition from MISSION mode to BROWNOUT mode is signaled by the IE_PLLFALL interrupt flag  
(SFR 0xE8[7]). The transition in the other direction is signaled by the IE_PLLRISE interrupt flag (SFR  
0xE8[6]), when the PLL becomes stable.  
Transitions from both LCD and SLEEP mode are initiated by wake-up timer timeout conditions or push-  
button events. When the PB pin is pulled high (pushbutton is pressed), the IE_PB interrupt flag (SFR  
0xE8[4]) is set, and when the wake-up timer times out, the IE_WAKE interrupt flag (SFR 0xE8[5]) is set.  
In the absence of system power, if the voltage margin for the LDO regulator providing 2.5 V to the internal  
circuitry becomes too low to be safe, the part automatically enters sleep mode (BAT_OK false). The battery  
voltage must stay above 3 V to ensure that BAT_OK remains true. Under this condition, the 71M6533 and  
71M6534 stays in SLEEP mode, even if the voltage margin for the LDO improves (BAT_OK true).  
Table 45 shows the circuit functions available in each operating mode.  
v1.1  
© 2007-2009 TERIDIAN Semiconductor Corporation  
55