Data Sheet 71M6531D/F-71M6532D/F  
V3P3D  
FDS 6531/6532 005  
LCD Segments  
(optional)  
ICE_E  
62 Ω  
62 Ω  
E_RST  
E_RXT  
E_TCLK  
62 Ω  
71M6531D/F  
71M6532D/F  
22 pF 22 pF 22 pF  
Figure 38: External Components for the Emulator Interface  
3.13 Connecting a Battery  
It is important that a valid voltage is connected to the VBAT pin at all times. For meters without a battery,  
VBAT should be connected directly to V3P3SYS. Designs for meters with batteries need to ensure that  
the meter functions even when the battery voltage decreases below the specified voltage for VBAT. This  
can be achieved by connecting a diode from V3P3SYS to VBAT. However, the battery test will yield in-  
accurate results if that technique is used, since the voltage at V3P3SYS will feed current to the VBAT pin.  
A better solution is shown in Figure 39: During the battery test, a DIO pin is activated as an output and  
applies a low voltage to the anode of the diode. This prevents the voltage at the power supply to influence  
the voltage at the VBAT pin.  
Power  
Supply  
V3P3SYS  
V3P3A  
DIO  
VBAT  
+
Batteryor  
Super-Cap  
-
71M6531/71M6532  
Figure 39: Connecting a Battery  
As mentioned in section 2.3, meters equipped with batteries need to contain code that transitions  
the chip to SLEEP mode as soon as the battery is attached in production. Otherwise, remaining in  
BROWNOUT mode would add unnecessary drain to the battery.  
3.14 Flash Programming  
Operational or test code can be programmed into the flash memory using either an in-circuit emulator or  
the Flash Programmer Module (TFP2) available from Teridian. The flash programming procedure uses  
the E_RST, E_RXTX and E_TCLK pins. The FL_BANK[2:0] register must be set to the value correspond-  
ing to the bank that is being programmed.  