 浏览型号71M6521DE-IM/F的Datasheet PDF文件第11页浏览型号71M6521DE-IM/F的Datasheet PDF文件第12页浏览型号71M6521DE-IM/F的Datasheet PDF文件第13页浏览型号71M6521DE-IM/F的Datasheet PDF文件第14页浏览型号71M6521DE-IM/F的Datasheet PDF文件第16页浏览型号71M6521DE-IM/F的Datasheet PDF文件第17页浏览型号71M6521DE-IM/F的Datasheet PDF文件第18页浏览型号71M6521DE-IM/F的Datasheet PDF文件第19页  
71M6521DE/71M6521FE  
Energy Meter IC  
DATASHEET  
JANUARY 2008  
1/32768Hz =  
30.518µs  
IB  
VB  
IA  
VA  
13/32768Hz = 397µs  
per mux cycle  
Figure 4: Samples from Multiplexer Cycle  
The end of each multiplexer cycle is signaled to the MPU by the CE_BUSY interrupt. At the end of each multiplexer cycle,  
status information, such as sag data and the digitized input signal, is available to the MPU.  
833ms  
20ms  
XFER_BUSY  
Interrupt to MPU  
Figure 5: Accumulation Interval  
Figure 5 shows the accumulation interval resulting from PRE_SAMPS = 42 and SUM_CYCLES = 50, consisting of 2100 samples  
of 397µs each, followed by the XFER_BUSY interrupt. The sampling in this example is applied to a 50Hz signal.  
There is no correlation between the line signal frequency and the choice of PRE_SAMPS or SUM_CYCLES (even though when  
SUM_CYCLES = 42 one set of SUM_CYCLES happens to sample a period of 16.6ms). Furthermore, sampling does not have to  
start when the line voltage crosses the zero line, and the length of the accumulation interval need not be an integer multiple of  
the signal cycles.  
It is important to note that the length of the accumulation interval, as determined by NACC, the product of SUM_CYCLES and  
PRE_SAMPS, is not an exact multiple of 1000ms. For example, if SUM_CYCLES = 60, and PRE_SAMPS = 00 (42), the  
resulting accumulation interval is:  
NACC  
fS  
6042  
32768Hz  
13  
2520  
τ =  
=
=
= 999.75ms  
2520.62Hz  
This means that accurate time measurements should be based on the RTC, not the accumulation interval.  
v1.0  
© 2005-2008 TERIDIAN Semiconductor Corporation  
Page: 15 of 101  
 
 
 