 浏览型号71M6521DE-IGT/F的Datasheet PDF文件第29页浏览型号71M6521DE-IGT/F的Datasheet PDF文件第30页浏览型号71M6521DE-IGT/F的Datasheet PDF文件第31页浏览型号71M6521DE-IGT/F的Datasheet PDF文件第32页浏览型号71M6521DE-IGT/F的Datasheet PDF文件第34页浏览型号71M6521DE-IGT/F的Datasheet PDF文件第35页浏览型号71M6521DE-IGT/F的Datasheet PDF文件第36页浏览型号71M6521DE-IGT/F的Datasheet PDF文件第37页  
71M6521DE/71M6521FE  
Energy Meter IC  
DATASHEET  
JANUARY 2008  
would be to clear them with a bit operation. This is to be avoided. The hardware implements bit operations as a byte wide read-  
modify-write hardware macro. If an interrupt occurs after the read, but before the write, its flag will be cleared unintentionally.  
The proper way to clear the flag bits is to write a byte mask consisting of all ones except for a zero in the location of the bit to  
be cleared. The flag bits are configured in hardware to ignore ones written to them.  
Interrupt Enable  
Interrupt Flag  
Interrupt Description  
External interrupt 0  
External interrupt 1  
External interrupt 2  
External interrupt 3  
External interrupt 4  
External interrupt 5  
External interrupt 6  
XFER_BUSY interrupt (int 6)  
RTC_1SEC interrupt (int 6)  
FWCOL0 interrupt (int 2)  
FWCOL1 interrupt (int 2)  
PLL_OK rise interrupt (int 4)  
PLL_OK fall interrupt (int 4)  
AUTOWAKE flag  
NAME  
LOCATION  
NAME  
LOCATION  
EX0  
EX1  
EX2  
EX3  
EX4  
SFR A8[[0]  
SFR A8[2]  
SFR B8[1]  
SFR B8[2]  
SFR B8[3]  
SFR B8[4]  
SFR B8[5]  
2002[0]  
IE0  
IE1  
SFR 88[1]  
SFR 88[3]  
SFR C0[1]  
SFR C0[2]  
SFR C0[3]  
SFR C0[4]  
SFR C0[5]  
SFR E8[0]  
SFR E8[1]  
SFR E8[3]  
SFR E8[2]  
SFRE8[6]  
SFRE8[7]  
SFRE8[5]  
SFRE8[4]  
IEX2  
IEX3  
IEX4  
IEX5  
EX5  
EX6  
IEX6  
EX_XFER  
EX_RTC  
IE_XFER  
IE_RTC  
IE_FWCOL0  
IE_FWCOL1  
IE_PLLRISE  
IE_PLLFALL  
IE_WAKE  
IE_PB  
2002[1]  
EX_FWCOL  
EX_PLL  
2007[4]  
2007[5]  
PB flag  
Table 47: Interrupt Enable and Flag Bits  
The AUTOWAKE and PB flag bits are shown in Table 47 because they behave similarly to interrupt flags, even though they are  
not actually related to an interrupt. These bits are set by hardware when the MPU wakes from a push button or wake timeout.  
The bits are reset by writing a zero. Note that the PB flag is set whenever the PB is pushed, even if the part is already awake.  
Each interrupt has its own flag bit, which is set by the interrupt hardware and is reset automatically by the MPU interrupt  
handler (0 through 5). XFER_BUSY and RTC_1SEC, which are OR-ed together, have their own enable and flag bits in addition  
to the interrupt 6 enable and flag bits (see Table 47), and these interrupts must be cleared by the MPU software.  
When servicing the XFER_BUSY and RTC_1SEC interrupts, special care must be taken to avoid lock-up  
conditions: If, for example, the XFER_BUSY interrupt is serviced, control must not return to the main program  
without checking the RTC_1SEC flag. If this rule is ignored, a RTC_1SEC interrupt appearing during the  
XFER_BUSY service routine will disable the processing of any XFER_BUSY or RTC_1SEC interrupt, since both  
interrupts are edge-triggered (see the Software User’s Guide SUG652X).  
The external interrupts are connected as shown in Table 47. The polarity of interrupts 2 and 3 is programmable in the MPU via  
the I3FR and I2FR bits in T2CON. Interrupts 2 and 3 should be programmed for falling sensitivity. The generic 8051 MPU  
literature states that interrupts 4 through 6 are defined as rising edge sensitive. Thus, the hardware signals attached to  
interrupts 5 and 6 are inverted to achieve the edge polarity shown in Table 47.  
SFR (special function register) enable bits must be set to permit any of these interrupts to occur. Likewise, each interrupt has  
its own flag bit that is set by the interrupt hardware and is reset automatically by the MPU interrupt handler (0 through 5).  
XFER_BUSY and RTC_1SEC, which are OR-ed together, have their own enable and flag bits in addition to the interrupt 6 enable  
and flag bits (see Table 47), and these interrupts must be cleared by the MPU software.  
v1.0  
© 2005-2008 TERIDIAN Semiconductor Corporation  
Page: 33 of 101  
 
 