 浏览型号71M6515H-IGTR/F的Datasheet PDF文件第19页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第20页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第21页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第22页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第24页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第25页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第26页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第27页  
71M6515H  
Energy Meter IC  
DATA SHEET  
MARCH 2008  
General Notes on Calibration  
The calibration procedures described below should be followed after  
interfacing the voltage and current sensors to the 71M6515H chip. When  
properly interfaced, the V3P3 power supply is connected to the meter  
neutral and is the DC reference for each input. Each voltage and current  
waveform, as seen by the 6515H, is scaled to be less than 250mV  
(peak).  
Voltage  
Current lags  
voltage  
(inductive  
)
Each meter phase must be calibrated individually. The procedures below  
show how to calibrate a meter phase with either three or five  
measurements. Note that there is no need to calibrate for VARh if the Wh  
measurement is calibrated correctly. Note that positive load angles  
correspond to lagging current (see Figure 13).  
Positive  
direction  
+60°  
Current  
-60°  
Current leads  
voltage  
For a typical calibration, a meter calibration system is used to apply a  
calibrated load, e.g. 240V at 30A, while interfacing the voltage and  
current sensors to the 71M6515H. This load should result in an ob-  
servable pulse rate at the PULSEW output depending on the selected  
energy per pulse. For example, 7.2kW will result in an energy rate  
corresponding to 7200Wh/3600s = 2Wh/s, i.e., when 7.2kW are applied  
per phase (resulting in a total power of 21.6kW, equivalent to 6Wh/s) and  
a Kh of 3.2 (Wh/pulse) has been configured, a pulse rate of 6Wh/3.2Whs  
(capacitive  
)
Voltage  
Using Energy  
Generating Energy  
= 1.875Hz will be established.  
Figure 13: Definition of Load Angles  
It is entirely possible to calibrate piece-wise, i.e. in segments, to compensate for non-linear sensors. For example, one set of  
calibration factors can be applied by the host when the current is below 0.5A, while another set is applied when the current is at  
or above 0.5A.  
Calibration Procedure for CT and Resistive Shunt  
A typical meter has phase and gain errors as shown by φS, AXI, and AXV in Figure 14. Following the typical meter convention of  
current phase being in the lag direction, the small amount of phase lead in a typical current sensor is represented as -φS. The  
errors shown in Figure 14 represent the sum of all gain and phase errors. They include errors in voltage attenuators, current  
sensors, signal conditioning circuits, and in ADC gains. In other words, no errors are made in the ‘input’ or ‘meter’ boxes.  
INPUT  
ERRORS  
METER  
IRMS  
I
φL  
−φS  
AXI  
=
=
IDEAL I, ACTUAL I AXI  
φ
L is phase lag  
φS is phase lead  
=
φ
)
IDEAL IV cos(  
L
W
Π
=
φ φ  
ACTUAL IV AXI AXV cos(  
)
S
L
VRMS  
V
AXV  
=
=
IDEAL V , ACTUAL V AXV  
ACTUAL IDEAL ACTUAL  
=
1
ERROR  
IDEAL  
IDEAL  
Figure 14: Watt Meter with Gain and Phase Errors.  
During the calibration phase, we measure errors and then introduce correction factors to nullify their effect. With three  
unknowns to determine, we must make at least three measurements. If we make more measurements, we can average the  
results.  