 浏览型号71M6515H-IGT/F的Datasheet PDF文件第9页浏览型号71M6515H-IGT/F的Datasheet PDF文件第10页浏览型号71M6515H-IGT/F的Datasheet PDF文件第11页浏览型号71M6515H-IGT/F的Datasheet PDF文件第12页浏览型号71M6515H-IGT/F的Datasheet PDF文件第14页浏览型号71M6515H-IGT/F的Datasheet PDF文件第15页浏览型号71M6515H-IGT/F的Datasheet PDF文件第16页浏览型号71M6515H-IGT/F的Datasheet PDF文件第17页  
71M6515H  
Energy Meter IC  
DATA SHEET  
MARCH 2008  
FUNCTIONAL DESCRIPTION  
THEORY OF OPERATION  
The 71M6515H integrates the primary functional blocks required to implement a solid-state electricity meter front end. Included  
on-chip are an analog front end (AFE), a digital computation engine (CE), a voltage reference, a real time clock, and I/O pins.  
Various current sensor technologies are supported including Current Transformers (CT), Resistive Shunts, and Rogowski  
(di/dt) Coils.  
In a typical application, the 71M6515H sequentially digitizes the voltage inputs on pins IA, VA, IB, VB, IC, VC and performs  
calculations to measure active energy (Wh), reactive energy (VARh), and apparent energy (VAh). In addition to these  
measurement functions, the real time clock function allows the device to record time of use (TOU) metering information for  
multi-rate applications.  
The 71M6515H contains a temperature-trimmed ultra-precise voltage reference, and the on-chip digital temperature compen-  
sation mechanism includes a temperature sensor and associated controls for correction of unwanted temperature effects on  
measurement. RTC accuracy can be greatly improved by supplying correction coefficients derived from crystal  
characterization. The combination of both features enables designers to produce electricity meters with exceptional accuracy  
over the industrial temperature range.  
Meter Equations  
The 71M6515H implements the equations in Table 1. Register EQU specifies the equation to be used. In one sample time,  
each of the six inputs is converted and the selected equation updated. In a typical application, IA, IB, IC are connected to  
current transformers that sense the current on each phase of the line voltage. VA, VB, and VC are typically connected to  
voltage sensors (resistor dividers) with respect to NEUTRAL. NEUTRAL is to be connected to V3P3A, the analog supply  
voltage. NEUTRAL is the zero reference for all analog measurements.  
EQU  
Watt & VAR Formula  
Application  
Channels used from MUX  
sequence  
Mux State:  
0
1
2
3
-
4
-
5
-
0
1*  
2
VA IA  
1 element, 2W 1ø  
IA  
IA  
IA  
IA  
IA  
IA  
VA  
VA  
VA  
VA  
VA  
VA  
-
VA(IA-IB)/2  
1 element, 3W 1ø  
IB  
IB  
IB  
IB  
IB  
-
-
-
VA IA + VB IB  
2 element, 3W 3 øDelta  
2 element, 4W 3ø Delta  
2 element, 4W 3ø Wye  
3 element, 4W 3ø Wye  
VB  
-
-
-
3*  
4*  
5
VA (IA - IB)/2 + VC IC  
VA(IA-IB)/2 + VB(IC-IB)/2)  
VA IA + VB IB + VC IC  
IC VC  
IC  
IC VC  
VB  
VB  
-
Note: Equations 1*, 3*, 4* available only when IMAGE = 00 (CT mode).  
Table 1: Meter Equations  
Table 2 shows how the elements of the meter are mapped for the six possible equations.  
Page: 13 of 57  
© 2005-2008 TERIDIAN Semiconductor Corporation  
V1.4