71M6513/71M6513H  
3-Phase Energy Meter IC  
A Maxim Integrated Products Brand  
DATA SHEET  
AUGUST 2011  
CE  
Address  
Name  
Default  
Description  
Meter voltage inputs must be above this threshold to prevent sag alarms.  
LSB = VMAX * 7.879810-9 V.  
+23,930,000  
(0x16D23AA)  
For example, if a sag threshold of 80V RMS is desired,  
0x31  
0x32  
SAG_THR  
SAG_CNT  
80  
2
SAG _THR =  
VMAX 7.8798109  
Number of consecutive voltage samples below SAG_THR before a sag alarm  
is declared (80*397µs = 31.8ms).  
80  
CE Transfer Variables  
When the MPU receives the XFER_BUSY interrupt, it knows that fresh data is available in the transfer variables. CE transfer  
variables are modified during the CE code pass that ends with an XFER_BUSY interrupt. They remain constant throughout  
each accumulation interval. In this data sheet, the names of CE transfer variables always end with _X.  
Fundamental Power Measurement Variables  
The table below describes each transfer variable for fundamental power measurement. All variables are signed 32 bit integers.  
Accumulated variables such as WSUM are internally scaled so they have at least 2x margin before overflow when the  
integration time is 1 second. Additionally, the hardware will not permit output values to ‘fold back’ upon overflow.  
CE  
Name  
Description  
Address  
0x42  
0x43  
0x44  
0x45  
0x46  
0x47  
0x48  
0x49  
WSUM_X  
W0SUM_X  
The signed sum: W0SUM_X+W1SUM_X+W2SUM_X  
The sum of Watt samples from each wattmeter element.  
LSB = 9.4045*10-13 VMAX IMAX / In_8 Wh.  
W1SUM_X  
W2SUM_X  
The signed sum: VAR0SUM_X+VAR1SUM_X+VAR2SUM_X  
VARSUM_X  
VAR0SUM_X  
VAR1SUM_X  
VAR2SUM_X  
The sum of VAR samples from each wattmeter element.  
LSB = 9.4045*10-13 VMAX IMAX / In_8 VARh.  
WSUM_X and VARSUM_X are the signed sum of Phase-A, Phase-B and Phase-C Wh or VARh values according to the  
metering equation specified in the I/O RAM register EQU. WxSUM_X is the Wh value accumulated for phase ‘x’ in the last  
accumulation interval and can be computed based on the specified LSB value.  
For example, with VMAX = 600V and IMAX = 208A, LSB (for WxSUM_X ) is 0.1173 µWh.  
Instantaneous Power Measurement Variables  
The FREQSEL Register selects the input phase used for frequency measurement and for the MAIN_EDGE counter. The  
frequency measurement is implemented using the frequency locked loop of the CE for the selected phase.  
IxSQSUM_X and VxSQSUM are the squared current and voltage samples acquired during the last accumulation interval.  
INSQSUM_X can be used for computing the neutral current.  
Page: 70 of 104  