78P2352 Dual Channel OC-3/STM1-E/E4 Line Interface Unit
ELECTRICAL SPECIFICATIONS (continued)
RECEIVER JITTER TRANSFER FUNCTION
The receiver clock recovery loop filter characteristics such that the receiver has the following transfer function.
The corner frequency of the PLL is approximately 120 kHz. Receiver jitter transfer function is not tested during
production test.
0
-1
-2
-3
-4
-5
-6
-7
-8
-9
-10
1.00E+03
1.00E+04
1.00E+05
1.00E+06
1.00E+07
Figure 17: Jitter Transfer
PARAMETER
Receiver Jitter transfer function
CONDITION
below 120 kHz
MIN
NOM
MAX
0.1
UNIT
dB
dB per
decade
Jitter transfer function roll-off
20
36