80C32/80C52  
The capture mode is illustrated in Figure 7.  
with the 16 bit value in registers RCAP2L and RCAP2H,  
which are preset by software. If EXEN2 = 1, then Timer  
2 still does the above, but with the added feature that a  
1-to-0 transition at external input T2EX will also trigger  
the 16 bit reload and set EXF2.  
Figure 7. Timer 2 in Capture Mode.  
The auto-reload mode is illustrated in Figure 8.  
Figure 8. Timer in Auto-Reload Mode.  
In the auto-reload mode there are again two options,  
which are selected by bit EXEN2 in T2CON.If  
EXEN2 = 0, then when Timer 2 rolls over it does not only  
set TF2 but also causes the Timer 2 register to be reloaded  
(MSB)  
(LSB)  
TF2  
EXF2  
RCLK  
TCLK  
EXEN2  
TR2  
C/T2  
CP/RL2  
The baud rate generator mode is selected by : RCLK = 1 and/or TCLK = 1.  
Symbol  
Position  
Name and Significance  
TF2  
T2CON.7  
Timer 2 overflow flag set by a Timer 2 overflow and must be cleared by software. TF2  
will not be set when either RCLK = 1 OR TCLK = 1.  
EXF2  
T2CON.6  
Timer 2 external flag set when either a capture or reload is caused by a negative  
transition on T2EX and EXEN2 = 1. When Timer 2 interrupt is enabled, EXF2 = 1 will  
cause the CPU to vector to the Timer 2 interrupt routine. EXF2 must be cleared by  
software.  
RCLK  
TCLK  
T2CON.5  
T2CON.4  
T2CON.3  
Receive clock flag. When set, causes the serial port to use Timer2 overflow pulses for its  
receive clock in modes 1 and 3. RCLK = 0 causes Timer 1 overflow to be used for the  
receive clock.  
Transmit clock flag. When set, causes the serial port to use Timer 2 overflow pulses for  
its transmit clock in modes 1 and 3. TCLK = 0 causes Timer 1 overflows to be used for  
the transmit clock.  
EXEN2  
Timer 2 external enable flag. When set, allows capture or reload to occur as a result of a  
negative transition on T2EX if Timer 2 is not being used to clock the serial port.  
EXEN2 = 0 causes Timer 2 to ignore events at T2EX.  
TR2  
T2CON.2  
T2CON.1  
Start/stop control for Timer 2. A logic 1 starts the timer.  
C/T2  
Timer or counter select. (Timer 2) 0 = Internal timer (OSC/12)  
1 = External event counter (falling edge triggered).  
CP/RL2  
T2CON.0  
Capture/Reload flag. When set, captures will occur on negative transitions at T2EX if  
EXEN 2 = 1. When cleared, auto reloads will occur either with Timer 2 overflows or  
negative transition at T2EX when EXEN2 = 1. When either RCLK = 1 or TCLK = 1, this  
bit is ignored and the timer is forced to auto-reload on Timer 2 overflow.  
8