TSL2562, TSL2563  
LOW-VOLTAGE  
LIGHT-TO-DIGITAL CONVERTER  
TAOS066J MAY 2007  
Functional Block Diagram  
Channel 0  
Visible and IR  
Integrating  
A/D Converter  
Channel 1  
IR Only  
V
= 2.4 V to 2.6 V  
DD  
Command  
Register  
ADC  
Register  
Address Select  
Interrupt  
ADDR SEL  
INT  
SCL  
SDA  
Two-Wire Serial Interface  
Detailed Description  
The TSL2562 and TSL2563 are second-generation ambient light sensor devices. Each contains two integrating  
analog-to-digital converters (ADC) that integrate currents from two photodiodes. Integration of both channels  
occurs simultaneously. Upon completion of the conversion cycle, the conversion result is transferred to the  
Channel 0 and Channel 1 data registers, respectively. The transfers are double-buffered to ensure that the  
integrity of the data is maintained. After the transfer, the device automatically begins the next integration cycle.  
2
Communication to the device is accomplished through a standard, two-wire SMBus or I C serial bus.  
Consequently, the TSL256x device can be easily connected to a microcontroller or embedded controller. No  
external circuitry is required for signal conditioning, thereby saving PCB real estate as well. Since the output  
of the TSL256x device is digital, the output is effectively immune to noise when compared to an analog signal.  
The TSL256x devices also support an interrupt feature that simplifies and improves system efficiency by  
eliminating the need to poll a sensor for a light intensity value. The primary purpose of the interrupt function is  
to detect a meaningful change in light intensity. The concept of a meaningful change can be defined by the user  
both in terms of light intensity and time, or persistence, of that change in intensity. The TSL256x devices have  
the ability to define a threshold above and below the current light level. An interrupt is generated when the value  
of a conversion exceeds either of these limits.  
Copyright E 2007, TAOS Inc.  
The LUMENOLOGY r Company  
r
r
2