TSL210
640
×
1 LINEAR SENSOR ARRAY
TAOS039B
−
MAY 2007
Absolute Maximum Ratings
†
Supply voltage range, V
DD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−0.3
V to 6 V
Input voltage range, V
I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−0.3
V to V
DD
+ 0.3V
Input clamp current, I
IK
(V
I
< 0 or V
I
> V
DD
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−20
mA to 20 mA
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
DD
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−25
mA to 25 mA
Voltage range applied to any output in the high impedance or
power-off state, V
O
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−0.3
V to V
DD
+ 0.3V
Continuous output current, I
O
(V
O
= 0 to V
DD
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−25
mA to 25 mA
Continuous current through V
DD
or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−100
mA to 100 mA
Analog output current range, I
O
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−25
mA to 25 mA
Operating free-air temperature range, T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−25°C
to 85°C
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−25°C
to 85°C
Lead temperature on connection pad for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
ESD tolerance, human body model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000 V
†
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “Recommended Operating Conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
Recommended Operating Conditions (see Figure 1 and Figure 2)
MIN
Supply voltage, V
DD
Input voltage, V
I
High-level input voltage, V
IH
Low-level input voltage, V
IL
Wavelength of light source,
λ
Clock frequency, f
clock
Sensor integration time, serial, t
int
Sensor integration time, parallel, t
int
Load capacitance, C
L
Load resistance, R
L
Operating free-air temperature, T
A
NOTE 1: SI must go low before the rising edge of the next clock pulse.
4.5
0
2
0
400
5
0.128
0.026
300
0
NOM
5
MAX
5.5
V
DD
V
DD
0.8
1000
5000
100
100
330
4700
70
UNIT
V
V
V
V
nm
kHz
ms
ms
pF
Ω
°C
Copyright
E
2007, TAOS Inc.
r
r
The
LUMENOLOGY
r
Company
4
www.taosinc.com