Absolute Maximum Ratings
†
Supply voltage range, V
DD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−0.3
V to 6 V
Input voltage range, V
I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−0.3
V to V
DD
+ 0.3V
Input clamp current, I
IK
(V
I
< 0) or (V
I
> V
DD
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−20
mA to 20 mA
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
DD
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−25
mA to 25 mA
Voltage range applied to any output in the high impedance or power-off state, V
O
. . .
−0.3
V to V
DD
+ 0.3 V
Continuous output current, I
O
(V
O
= 0 to V
DD
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−25
mA to 25 mA
Continuous current through V
DD
or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−40
mA to 40 mA
Analog output current range, I
O
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−25
mA to 25 mA
Maximum light exposure at 638 nm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 mJ/cm
2
Operating free-air temperature range, T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−25°C
to 85°C
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
−25°C
to 85°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
†
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “Recommended Operating Conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
Recommended Operating Conditions (see Figure 1 and Figure 2)
MIN
Supply voltage, V
DD
Input voltage, V
I
High-level input voltage, V
IH
Low-level input voltage, V
IL
Wavelength of light source,
λ
Clock frequency, f
clock
Sensor integration time, Serial, t
int
(see Note 1)
Sensor integration time, Parallel, t
int
(see Note 1)
Setup time, serial input, t
su(SI)
Hold time, serial input, t
h(SI)
(see Note 2)
Operating free-air temperature, T
A
3
0
2
0
400
5
0.11375
0.06575
20
0
0
70
NOM
5
MAX
5.5
V
DD
V
DD
0.8
1000
8000
100
100
UNIT
V
V
V
V
nm
kHz
ms
ms
ns
ns
°C
NOTES: 1. Integration time is calculated as follows:
t
int (min)
= (768
−
18)
y
clock period + 20
ms
where
768
is the number of pixels in series,
18
is the required logic setup clocks, and
20
ms
is the pixel charge transfer time (t
qt
)
2. SI must go low before the rising edge of the next clock pulse.