TAK CHEONG
ELECTRICAL CHARACTERIZATION
(
T
A
= 25°C unless otherwise noted)
Zener Voltage
(Note 3.)
Device
(Note 2.)
Device
Marking
Min
1N957B
1N958B
1N959B
1N960B
1N961B
1N962B
1N963B
1N964B
1N965B
1N966B
1N967B
1N968B
1N969B
1N957B
1N958B
1N959B
1N960B
1N961B
1N962B
1N963B
1N964B
1N965B
1N966B
1N967B
1N968B
1N969B
6.460
7.125
7.790
8.645
9.500
10.45
11.40
12.35
14.25
15.20
17.10
19.00
20.90
V
Z
(Volts)
Nom
6.8
7.5
8.2
9.1
10
11
12
13
15
16
18
20
22
Max
7.140
8.875
8.610
9.555
10.500
11.55
12.60
13.65
15.75
16.8
18.90
21.00
23.10
@I
ZT
(mA)
18.5
16.5
15
14
12.5
11.5
10.5
9.5
8.5
7.8
7
6.2
5.6
Li censed b y
ON Semico nd uctor
,
A tradem ark o f
semico nd uctor
Com ponents I ndustri es, LLC for
Zener Tec hnolo gy
and
Pro ducts
.
Zener Impedance
(Note 4.)
Z
ZT
@I
ZT
(Ω)
4.5
5.5
6.5
7.5
8.5
9.5
11.5
13
16
17
21
25
29
Z
ZK
@I
ZK
(Ω)
700
700
700
700
700
700
700
700
700
700
750
750
750
(mA)
1
0.5
0.5
0.5
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
Leakage Current
IR @VR = 1V
(uA)
150
75
50
25
10
5
5
5
5
5
5
5
5
(Volts)
5.2
5.7
6.2
6.9
7.6
8.4
9.1
9.9
11.4
12.2
13.7
15.2
16.7
I
ZM
(Note 5.)
(mA)
47
42
38
35
32
28
26
24
21
19
17
15
14
VF Forward Voltage = 1.5V max @ I
F
= 200mA for all types
2. TOLERANCE AND VOLTAGE DESIGNATION
The type numbers listed have a standard tolerance on the nominal zener voltage of
±5%.
3. ZENER VOLTAGE (V
Z
) MEASUREMENT
The zener voltage (V
Z
) is tested under pulse condition. The measured
V
Z
is guaranteed to be within specification with device
junction in thermal equilibrium.
4. ZENER IMPEDANCE (Z
Z
) DERIVATION
Z
ZT
and Z
ZK
are measured by dividing the AC voltage drop across the device by the AC current applied. The specified limits are
for I
Z(AC)
= 0.1 I
Z(DC)
with AC frequency = 60Hz.
5. MAXIMUM ZENER CURRENT RATINGS (I
ZM
)
Values shown are based on the JEDEC rating of 400mW where the actual zener voltage (V
Z
) is known at the operation point, the
zener current may be increased and is limited by the derating curve.
Number: DB-072
Apr. 2010 / D
Page 2