RELIABILITY DATAꢀ
4/4
Specifled Value
Item
BRC1608, BRL2012, BRC2016,
Test Method and Remarks
NRH24, NR30/40/60/80,
NRG40 Type
BRL2518, BRL3225
NR10050 Type
Type
Inductance change:Within±10%
18.Loading under damp
BRC1608,BRL2012,BRC2016,BRL2518,BRL3225Type:
No significant abnormality in appearance.
Temperature
Humidity
60±2℃
heat
90~95%RH
Rated current
1000hours.
Applied current
Time
Recovery: At least 2hrs of recovery under the standard
condition after the test, followed by the measurement
within 48 hrs.
5
NRH24, NR30/40/60/80, NRG40Type, NR10050 Type:
The test samples shall be soldered to the test board
by the reflow.
The test samples shall be placed in thermostatic oven
set at specified temperature and humidity and applied
the rated current continuously as shown in below
table.
Temperature
Humidity
60±2℃
90~95%RH
Rated current
500±2hour
Applied current
Time
ꢀꢀꢀ
19.Low temperature life test
Inductance change:Within±10%
BRC1608,BRL2012,BRC2016,BRL2518,BRL3225Type:
No significant abnormality in appearance.
Temperature
Duration
ー40±2℃
1000hours
Recovery: At least 2hrs of recovery under the standard
condition after the test, followed by the measurement
within 48 hrs.
NRH24, NR30/40/60/80, NRG40Type, NR10050 Type:
The test samples shall be soldered to the test board
by the reflow.
After that, the test samples shall be placed at test
conditions as shown in below table.
Temperature
Time
-40±3℃
500±24hour
Inductance change:
Within±10%
Inductance change:
Within±10%
BRC1608,BRL2012,BRC2016,BRL2518,BRL3225Type:
20.High temperature life
Temperature
Duration
85±2℃
1000hours
test
No significant abnormality in
No significant abnormality in
Recovery: At least 2hrs of recovery under the standard
condition after the test, followed by the measurement
within 48 hrs.
appearance.
appearance.
NR10050 Type:
Temperature
105±3℃
Time
500±24hour
Recovery: At least 2hrs of recovery under the standard
condition after the test, followed by the measurement
within 48 hrs.
Inductance change:
21.Loading at high
NRH24, NR30/40/60/80, NRG40Type
:
Within±10%
temperature life test
The test samples shall be soldered to the test board
by the reflow soldering
No significant abnormality in
appearance.
Temperature
Applied current
Time
85±2℃
Rated current
500±24hour
22.Standard condition
Standard test condition : Unless otherwise specified, temperature is 20±15% and 65±20%of
relative humidity.
When there are question concerning measurement result : In order to provide correlation date, the
test shall be condition of 20±2℃ of temperature, 65±5% relative humidity.
Inductance is in accordance with our measured value.
!