■ RELIABILITY DATA
23.Low temperature life test
Inductance change :Within±10%
Q→ R12~4R7:30 min.
5R6~330:25 min.
LEM2520
390~820:20 min.
101:15 min.
LB3218
LB2518
LB2016
LB2012
LB1608
LBMF1608
LBC3225
LBR2518
CB2518
LBC2518
LBR2012
CB2016
CBC2518
LBC2016
LBC2012
CB2012
Inductance change:Within±10%
No significant abnormality in appearance.
CBC3225
CBL2012
CBMF1608
LBM2016
CBC2016
CBC2012
【Test Methods and Remarks】
LEM・LB・LBC・LBR・CB・CBC・CBL・LBM・LBMF・CBMF
Temperature:-40±2℃
Duration:1000 hrs
Recovery:At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs.
LEM:Recovery
At least 1 hr of recovery under the standard condition after the test, followed by the measurement within 2 hrs.
24.Standard condition
LEM2520
LB3218
LB2518
LB2016
LB2012
LB1608
LBMF1608
Standard test conditions
LBC3225
LBR2518
CB2518
LBC2518
LBR2012
CB2016
CBC2518
LBC2016
LBC2012
Unless specified, Ambient temperature is 20±15℃ and the Relative humidity is 65±
20%. If there is any doubt about the test results, further measurement shall be had
within the following limits:
CB2012
Ambient Temperature: 20±2℃
CBC3225
CBL2012
CBMF1608
LBM2016
CBC2016
CBC2012
Relative humidity: 65±5%
Inductance value is based on our standard measurement systems.
*This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.