■ RELIABILITY DATA
1. Operating Temperature Range
BRC1608, BRL2012, BRC2016, BRC2518,
BRFL2518, BRL2518, BRL3225 Type
ー25~+105℃
NR30/40/50/60/80, NRV30, NRG40,
NRH24/30, NRS50/60 Type
ー25~+120℃
ー25~+105℃
NR10050 Type
【Test Method and Remarks】
Including self-generated heat
2. Storage Temperature Range
BRC1608, BRL2012, BRC2016, BRC2518,
BRFL2518, BRL2518, BRL3225 Type
NR30/40/50/60/80, NRV30, NRG40,
NRH24/30, NRS50/60 Type
ー40~+85℃
NR10050 Type
【Test Method and Remarks】
BRC1608, BRL2012, BRC2016, BRC2518, BRFL2518, BRL2518, BRL3225 Type, NR30/40/50/60/80, NRV30, NRG40, NRH24/30, NRS50/60 Type : 0 to 40℃ for the product with taping.
NR10050 Type : 0~40℃ for the product with taping.
3. Rated current
BRC1608, BRL2012, BRC2016, BRC2518,
BRFL2518, BRL2518, BRL3225 Type
NR30/40/50/60/80, NRV30, NRG40,
NRH24/30, NRS50/60 Type
Within the specified tolerance
NR10050 Type
4. Inductance
BRC1608, BRL2012, BRC2016, BRC2518,
BRFL2518, BRL2518, BRL3225 Type
NR30/40/50/60/80, NRV30, NRG40,
NRH24/30, NRS50/60 Type
Within the specified tolerance
NR10050 Type
【Test Method and Remarks】
BRC1608, BRL2012, BRC2016, BRC2518, BRFL2518, BRL2518, BRL3225 Type : LCR Meter : HP 4285A or equivalent, Measuring frequency : Specified frequency
NR30/40/50/60/80, NRV30, NRG40, NRH24/30, NRS50/60 Type : LCR Meter : HP 4285A or equivalent, 100KHz, 1V
NR10050 Type
: LCR Meter : HP 4263A or equivalent, 100KHz, 1V
5. DC Resistance
BRC1608, BRL2012, BRC2016, BRC2518,
BRFL2518, BRL2518, BRL3225 Type
NR30/40/50/60/80, NRV30, NRG40,
NRH24/30, NRS50/60 Type
Within the specified tolerance
NR10050 Type
【Test Method and Remarks】
DC ohmmeter : HIOKI 3227 or equivalent
6. Self resonance frequency
BRC1608, BRL2012, BRC2016, BRC2518,
BRFL2518, BRL2518, BRL3225 Type
NR30/40/50/60/80, NRV30, NRG40,
NRH24/30, NRS50/60 Type
Within the specification
NR10050 Type
【Test Method and Remarks】
BRC1608, BRL2012, BRC2016, BRC2518, BRFL2518, BRL2518, BRL3225 Type, NR30/40/50/60/80, NRV30, NRG40, NRH24/30, NRS50/60 Type, NR10050 Type :
Inpedance analyzer/material analyzer : HP4291A or equivalent HP4191A, 4192A or equivalent
7. Temperature characteristic
BRL2012, BRC2016, BRL2518, BRL3225, BRC2518, BRFL2518
Inductance change : Within ±15%
BRC1608, BRL2012, BRC2016, BRC2518,
BRFL2518, BRL2518, BRL3225 Type
BRC1608
Inductance change : Within ±20%
NR30/40/50/60/80, NRV30, NRG40,
NRH24/30, NRS50/60 Type
Inductance change : Within ±20%
NR10050 Type
【Test Method and Remarks】
BRC1608, BRL2012, BRC2016, BRC2518, BRFL2518, BRL2518, BRL3225 Type, NR30/40/50/60/80, NRV30, NRG40, NRH24/30, NRS50/60 Type, NR10050 Type :
Measurement of inductance shall be taken at temperature range within -25℃~+85℃.
With reference to inductance value at +20℃., change rate shall be calculated.
Change of maximum inductance deviation in step 1 to 5
Temperature at step 1
Temperature at step 2
Temperature at step 3
Temperature at step 4
Temperature at step 5
20℃
Minimum operating temperature
20℃ (Standard temperature)
Maximum oparating temperature
20℃
*This catalog contains the typical specification only due to the limitation of space. When you consider purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
wound0407_reli_e-01