RELIABILITY DATA  
Multilayer chip inductors and beads  
16. Loading at High Temperature  
BK0402  
BK0603  
BK1005  
BKH1005  
BK1608  
BK2125  
AppearanceNo significant abnormality  
Impedance changeWithin ±30%  
BK2010  
ARRAY  
BK3216  
BKP0603  
BKP1005  
BKP1608  
BKP2125  
CK1608  
No mechanical damage.  
Inductance changeWithin ±20%ꢀ Q changeWithin ±30%  
CK2125  
CKS2125  
CKP2012  
CKP2016  
CKP2520  
NM2012  
NM2520  
LK1005  
No mechanical damage.Inductance changeWithin ±20%  
No mechanical damage.Inductance changeWithin ±30%  
No mechanical damage.Inductance changeWithin ±10%ꢀ Q changeWithin ±30%  
No mechanical damage.  
LK1608  
Inductance change0.047 to 12.0μHWithin ±10%ꢀ 15.0 to 33.0μHWithin ±15%ꢀ Q changeWithin ±30%  
LK2125  
No mechanical damage.Inductance changeWithin ±20%ꢀ Q changeWithin ±30%  
HK0402  
HK0603  
HK1005  
HK1608  
HK2125  
HKQ0603S  
HKQ0603U  
AQ105  
No mechanical damage.  
Inductance changeWithin ±10%ꢀ Q changeWithin ±20%  
Test Methods and Remarks】  
BK, BKH Series:  
Temperature125±3℃  
Applied currentRated current  
24  
Duration500  
hrs  
0  
Recovery2 to 3 hrs of recovery under the standard condition after the removal from test chamber. See Note 1)  
LKCKCKSCKPNMHKHKQAQBKP Series:  
Temperature85±2LKCKCKSCKPNMBKP Series)  
85±2HK16082125)  
85±2HK1005, AQ105 operating temperature range 55 to 85℃)  
125±2HK0402, HK0603, HK1005, HKQ0603S, HKQ0603U, AQ105 operating temperature range 55 to 125℃)  
Applied currentRated current  
Duration500±12 hrs  
Recovery2 to 3 hrs of recovery under the standard condition after the test. See Note 1)  
Note on standard condition: "standard condition" referred to herein is defined as follows:  
5 to 35of temperature, 45 to 85% relative humidity, and 86 to 106kPa of air pressure.  
When there are questions concerning measurement results:  
In order to provide correlation data, the test shall be conducted under condition of 20±2of temperature, 60 to 70% relative humidity, and 86 to 106kPa of air pressure. Unless other-  
wise specified, all the tests are conducted under the "standard condition."  
(Note 1) Measurement shall be made after 48±2 hrs of recovery under the standard condition.  
This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.  
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.  
mlci0109_reli_e-01  
mlci0109_reli-PRP12  
 复制成功!