■ RELIABILITY DATA
12.Resistance to Soldering
Appearance:
No abnormality
Capacitance change:
Dissipation factor :
Insulation resistance:
Within±15%(HMK), ±10%(QMK, SMK)
Initial value
Initial value
Specified Value
Withstanding voltage(between terminals): No abnormality
【Test Methods and Remarks】
Preconditioning:Thermal treatmen(t at 150℃ for 1hr) Note1
Solder temperature:270±5℃
Duration:3±0.5sec.
Preheating conditions: 80 to 100℃, 2 to 5 min.
150 to 200℃, 2 to 5min.
Recovery : 24±2hrs under the standard condition Note3
13.Temperature Cycle(Thermal Shock)
Appearance:
Capacitance change: Within±15%(HMK), ±7.5%(QMK, SMK)
Dissipation factor: Initial value
No abnormality
Specified Value
Insulation resistance: Initial value
【Test Methods and Remarks】
Preconditioning:Thermal treatmen(t at 150℃ for 1hr) Note1
+0
Conditions for 1 cycle/ Step 1: Minimum operating temperature
℃ 30±3min.
-3
Step 2: Normal temperature
Step 3: Maximum operating temperature
Step 4: Normal temperature
2 to 3min.
+0
-3
℃ 30±3min.
2 to 3min.
Number of cycles:5 times
Recovery : 24±2hrs under the standard condition Note3
14.Humidit(y Steady state)
Appearance:
No abnormality
Capacitance change: Within±15%
Specified Value
Dissipation factor :
7%ma(x HMK), 5%ma(x QMK, SMK).
Insulation resistance: 25MΩμF or 1000MΩ, whichever is smaller.
【Test Methods and Remarks】
Preconditioning:Thermal treatmen(t at 150℃ for 1hr) Note1
Temperature:40±2℃
Humidity:90 to 95%RH
+24
Duration: 500
hrs
-0
Recovery : 24±2hrs under the standard condition Note3
15.Humidity Loading
Appearance:
No abnormality
Capacitance change: Within±15%
Specified Value
Dissipation factor:
7%ma(x HMK), 5%ma(x QMK, SMK).
Insulation resistance: 10MΩμF or 500MΩ, whichever is smaller.
【Test Methods and Remarks】
According to JIS 5102 clause 9.9.
Preconditioning:Voltage treatment Note2
Temperature:40±2℃
Humidity:90 to 95%RH
Applied voltage:Rated voltage
Charge/discharge current:50mA max.
+24
Duration: 500
hrs
-0
Recovery : 24±2hrs under the standard condition Note3
16.High Temperature Loading
Appearance:
No abnormality
Capacitance change: Within±15%
Specified Value
Dissipation factor:
7%ma(x HMK), 5%ma(x QMK, SMK).
Insulation resistance: 50MΩμF or 1000MΩ, whichever is smaller.
【Test Methods and Remarks】
According to JIS 5102 clause 9.10.
Preconditioning:Voltage treatment Note2
Temperature:125±3℃(B7, C7), 85±2℃(BJ)
Applied voltage:Rated voltage×2(HMK)
Rated voltage×1.5(QMK)
Rated voltage×1.2(SMK)
Charge/discharge current:50mA max.
+24
Duration: 1000
hrs
-0
Recovery : 24±2hrs under the standard condition Note3
Note1 Thermal treatment : Initial value shall be measured after test sample is heat-treated at 150+0/-10℃ for an hour and kept at room temperature for 24±2hours.
Note2 Voltage treatment : Initial value shall be measured after test sample is voltage-treated for an hour at both the temperature and voltage specified in the test conditions, and
kept at room temperature for 24±2hours.
Note3 Standard condition: Temperature: 5 to 35℃, Relative humidity: 45 to 85 % RH, Air pressure: 86 to 106kPa
When there are questions concerning measurement results, in order to provide correlation data, the test shall be conducted under the following condi-
tion.
Temperature: 20±2℃, Relative humidity: 60 to 70 % RH, Air pressure: 86 to 106kPa
Unless otherwise specified, all the tests are conducted under the "standard condition".