 浏览型号PQ60120EML04PRS的Datasheet PDF文件第1页浏览型号PQ60120EML04PRS的Datasheet PDF文件第2页浏览型号PQ60120EML04PRS的Datasheet PDF文件第3页浏览型号PQ60120EML04PRS的Datasheet PDF文件第4页浏览型号PQ60120EML04PRS的Datasheet PDF文件第6页浏览型号PQ60120EML04PRS的Datasheet PDF文件第7页浏览型号PQ60120EML04PRS的Datasheet PDF文件第8页浏览型号PQ60120EML04PRS的Datasheet PDF文件第9页  
Input:  
35-75 V  
Output:  
12 V  
Current:  
4 A  
Package:  
Eighth-brick  
Technical Specification  
95  
90  
85  
80  
75  
70  
65  
60  
92.0  
91.5  
91.0  
90.5  
90.0  
89.5  
89.0  
88.5  
88.0  
25 C  
40 C  
55 C  
35 Vin  
48 Vin  
75 Vin  
0
100  
200  
300  
400  
500  
0.0  
0.4  
0.8  
1.3  
1.7  
2.1  
2.5  
2.9  
3.3  
3.8  
4.2  
Air Flow (LFM)  
Load Current (A)  
Figure 1: Efficiency at nominal output voltage vs. load current for min-  
Figure 2: Efficiency at nominal output voltage and 60% rated power vs.  
imum, nominal, and maximum input voltage at 25  
°C.  
airflow rate for ambient air temperatures of 25  
(nominal input voltage).  
°C, 40°C, and 55°C  
7
6
5
4
3
2
1
0
5.0  
4.5  
4.0  
3.5  
3.0  
2.5  
2.0  
25 C  
40 C  
55 C  
35 Vin  
48 Vin  
75 Vin  
0
100  
200  
300  
400  
500  
0.0  
0.4  
0.8  
1.3  
1.7  
2.1  
2.5  
2.9  
3.3  
3.8  
4.2  
Air Flow (LFM)  
Load Current (A)  
Figure 3: Power dissipation at nominal output voltage vs. load current  
Figure 4: Power dissipation at nominal output voltage and 60% rated  
power vs. airflow rate for ambient air temperatures of 25 C, 40 C, and  
55 C (nominal input voltage).  
for minimum, nominal, and maximum input voltage at 25  
°C.  
°
°
°
4.5  
4.0  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
400 LFM (2.0 m/s)  
300 LFM (1.5 m/s)  
200 LFM (1.0 m/s)  
100 LFM (0.5 m/s)  
50 LFM (0.25 m/s)  
Semiconductor junction temperature is  
within 1 C of surface temperature  
0
25  
40  
55  
70  
85  
°
Ambient Air Temperature (oC)  
Figure 5: Maximum output power derating curves vs. ambient air tem-  
perature for airflow rates of 50 LFM through 400 LFM with air flowing  
across the converter from pin 3 to pin 1 (nominal input voltage).  
Figure 6: Thermal plot of converter at 4.2 amp load current (50W) with  
55 C air flowing at the rate of 200 LFM. Air is flowing across the con-  
verter from pin 3 to pin 1 (nominal input voltage).  
°