 浏览型号PQ60050QTA30NRS的Datasheet PDF文件第5页浏览型号PQ60050QTA30NRS的Datasheet PDF文件第6页浏览型号PQ60050QTA30NRS的Datasheet PDF文件第7页浏览型号PQ60050QTA30NRS的Datasheet PDF文件第8页浏览型号PQ60050QTA30NRS的Datasheet PDF文件第9页浏览型号PQ60050QTA30NRS的Datasheet PDF文件第10页浏览型号PQ60050QTA30NRS的Datasheet PDF文件第11页浏览型号PQ60050QTA30NRS的Datasheet PDF文件第13页  
35-75 V  
5.0 V  
Input:  
Output:  
Current:  
Package:  
30 A  
Quarter-brick  
Technical Specification  
Figure F shows three turn-on scenarios, where a Startup Inhibit  
Period is initiated at t0, t1, and t2:  
Startup Inhibit Period: The Startup Inhibit Period ensures that  
the converter will remain off for approximately 200ms when it is  
shut down for any reason. When an output short is present, this  
generates a 5Hz “hiccup mode,” which prevents the converter  
from overheating. In all, there are seven ways that the converter  
can be shut down, initiating a Startup Inhibit Period:  
Before time t0, when the input voltage is below the UVL threshold,  
the unit is disabled by the Input Under-Voltage Lockout feature.  
When the input voltage rises above the UVL threshold, the Input  
Under-Voltage Lockout is released, and a Startup Inhibit Period is  
initiated. At the end of this delay, the ON/OFF pin is evaluated,  
and since it is active, the unit turns on.  
• Input Under-Voltage Lockout  
• Input Over-Voltage Shutdown (not present in Quarter-brick)  
• Output Over-Voltage Protection  
• Over Temperature Shutdown  
• Current Limit  
At time t1, the unit is disabled by the ON/OFF pin, and it cannot  
be enabled again until the Startup Inhibit Period has elapsed.  
When the ON/OFF pin goes high after t2, the Startup Inhibit  
Period has elapsed, and the output turns on within the typical  
Turn-On Time.  
• Short Circuit Protection  
• Turned off by the ON/OFF input  
V
in  
Under-Voltage  
Lockout Turn-On  
Threshold  
ON/OFF  
(pos logic)  
ON  
OFF  
ON  
OFF  
ON  
4ms (typical  
turn on time)  
V
out  
200ms  
(typical start-up  
inhibit period)  
200ms  
200ms  
t
t0  
t1  
t2  
Figure F: Startup Inhibit Period (turn-on time not to scale)  
Product # PQ60050QTA30  
Phone 1-888-567-9596  
www.synqor.com  
Doc.# 005-2QT650C Rev. E  
05/20/09  
Page 12