Technical Specification
Eighth
48V 5.0V
10A
out
in
Brick
ELECTRICAL CHARACTERISTICS (Continued)
Parameter
P
Min.
Typ.
Max.
Units Notes & Conditions
FEATURE CHARACTERISTICS
Switching Frequency
230
260
290
kHz
ON/OFF Control (Option P)
Off-State Voltage
-2
0.8
18
V
V
On-State Voltage
2.4
ON/OFF Control (Option N)
Off-State Voltage
2.4
-2
18
V
On-State Voltage
0.8
V
ON/OFF Control (Either Option)
Pull-Up Voltage
Figures A, B
V
Vin/6.5
40
9.2
Pull-Up Resistance
kΩ
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
Over-Temperature Shutdown
Over-Temperature Shutdown Restart Hysteresis
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia)
Calculated MTBF (MIL-217)
Demonstrated MTBF
-10
+10
+10
127
%
Measured across Pins 8 & 4; Figure C
Measured across Pins 8 & 4
%
%
117
122
125
10
Over full temp range; % of nominal Vout
Average PCB Temperature
°C
°C
106 Hrs. TR-NWT-000332; 80% load,300LFM, 40 C T
o
2.4
1.4
TBD
a
a
106 Hrs. MIL-HDBK-217F; 80% load, 300LFM, 40 C T
o
106 Hrs. Field demonstrated MTBF
STANDARDS COMPLIANCE
Parameter
P
Notes
STANDARDS COMPLIANCE
UL/cUL 60950
File # E194341, Basic insulation & pollution degree 2
Certified by TUV
EN60950
72/23/EEC
93/68/EEC
Needle Flame Test (IEC 695-2-2)
IEC 61000-4-2
test on entire assembly; board & plastic components UL94V-0 compliant
ESD test, 8kV - NP, 15kV air - NP
GR-1089-CORE
Section 7 - electrical safety, Section 9 - bonding/grounding
Telcordia (Bellcore) GR-513
•
An external input fuse must always be used to meet these safety requirements
QUALIFICATION TESTING
Parameter
P
# Units Test Conditions
QUALIFICATION TESTING
Life Test
32
95% rated Vin and load, units at derating point, 1000 hours
10-55Hz sweep, 0.060” total excursion,1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x and y axis, 1 drop in z axis
-40°C to 100°C, unit temp. ramp 15°C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10°C to Tmax+10°C, 5°C steps, Vin = min to max, 0-105% load
85°C, 85% RH, 1000 hours, 2 minutes on and 6 hours off
MIL-STD-883, method 2003
Vibration
5
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
5
10
5
5
5
Solderability
15 pins
•
Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we supply
robust, reliable product. Contact factory for more information about Proof of Design and Proof of Manufacturing processes.
OPTIONS
PATENTS
SynQor provides various options for Enable Logic and Pin Length SynQor is protected under various patents, including but not lim-
for this family of DC/DC converters. Please consult the last page ited to U.S. Patent # 5,999,417.
of this specification sheet for information on available options.
Product # PQ60050EML10
Phone 1-888-567-9596
Doc.# 005-2EM650E Rev. A
5/22/03
Page 4